Adjustable wrench that 

opens to 1" (25 mm)  or 

hex-head socket wrench 

Utility knife 

Level

Tape measure

Pliers

Caulking gun and 

compound (for installing 

new exhaust vent)

Parts package is located in dryer drum. Check that all parts  

are included.

noTE:

 If installing dryer on pedestal, do not use leveling legs.

optional Equipment: 

(Not supplied with dryer)

Refer to your Use and Care Guide for information about 

accessories available for your dryer.

Parts supplied: 

Leveling legs (4)

“Y” connector

Short inlet hose

Long inlet hose

Rubber washer

Parts needed: 

(Not supplied with dryer)

Check local codes. Check existing electrical supply and venting. 

See “Electrical Requirements” and “Venting Requirements” 

before purchasing parts.

Check code requirements. Some codes limit, or do not permit, 

installing dryer in garages, closets, mobile homes, or sleeping 

quarters. Contact your local building inspector.

LOCATION REQUIREMENTS

You will need:

A location allowing for proper exhaust installation. See  

 

“Venting Requirements.”

A separate 30 amp circuit.

 

If using power supply cord, a grounded electrical outlet  

 

located within 2 ft. (610 mm) of either side of dryer. See 

“Electrical Requirements.”

Floor must support dryer weight of 200 lbs. (90.7 kg). Also 

 

consider weight of companion appliance.

Cold water faucets located within 4 ft. (1.2 m) of the water fill 

 

valves, and water pressure of 20-100 psi (137.9-689.6 kPa). 

You may use the water supply for your washer using the  

“Y” connector and short hose (if needed) which are provided.

20-100 psi (138-690 kPa) for best performance.

 

Level floor with maximum slope of 1" (25 mm) under entire 

 

dryer. If slope is greater than 1" (25 mm), install Extended  

Dryer Feet Kit, Part Number 279810. If not level, clothes  

may not tumble properly and automatic sensor cycles may  

not operate correctly.

For each arrangement, consider allowing more space for ease  

of installation and servicing; spacing for companion appliances  

and clearances for walls, doors, and floor moldings. Space  

must be large enough to allow door to fully open. Add spacing  

on all sides of dryer to reduce noise transfer. If a closet door  

or louvered door is installed, top and bottom air openings  

in door are required.

Summary of Contents for WED7990XU

Page 1: ...IC DRYER INSTALLATION INSTRUCTIONS INSTALLATION NOTES Date of purchase __________________________________ Date of installation _ _______________________________ Installer _________________________________________ Model number ____________________________________ Serial number ____________________________________ Para obtener acceso al manual de uso y cuidado en español o para obtener información a...

Page 2: ...ather the required tools and parts before starting installation Tools needed Flat blade screwdriver 2 Phillips screwdriver Wire stripper direct wire installations Tin snips new vent installations Vent clamps 1 4 nut driver recommended DRYER SAFETY ...

Page 3: ... Requirements A separate 30 amp circuit If using power supply cord a grounded electrical outlet located within 2 ft 610 mm of either side of dryer See Electrical Requirements Floor must support dryer weight of 200 lbs 90 7 kg Also consider weight of companion appliance Cold water faucets located within 4 ft 1 2 m of the water fill valves and water pressure of 20 100 psi 137 9 689 6 kPa You may use...

Page 4: ...to shut off at end of automatic sensor cycles resulting in longer drying times Installation spacing for recessed area or closet All dimensions show recommended spacing allowed with tested spacing of 0 0 mm clearance on sides and rear Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spa...

Page 5: ...for it here This dryer is manufactured ready to install with a 3 wire electrical supply connection The neutral ground conductor is permanently connected to the neutral conductor white wire within the dryer If the dryer is installed with a 4 wire electrical supply connection the neutral ground conductor must be removed from the external ground connector green screw and secured under the neutral ter...

Page 6: ...r visible Now stand the dryer on its feet Slide the dryer until it is close to its final location Leave enough room for electrical connection and to connect the exhaust vent Electrical Connection Options 1 Choose electrical connection type Power supply cord 4 wire receptacle NEMA Type 14 30R Follow only steps for 4 wire power supply cord connection Then go to Venting Requirements Power supply cord...

Page 7: ...1 for 4 wire power supply cord connection or step 1 for 3 wire power supply cord connection Attach power supply cord to strain relief 2 Attach power supply cord strain relief Remove screws from 3 4 19 mm UL listed strain relief UL marking on strain relief Put two clamp section tabs into hole below terminal block opening with one tab pointing up and one pointing down Hold in place and tighten strai...

Page 8: ...e terminals with upturned ends F 3 4 19 mm UL listed strain relief G Ring terminals A B B Connect remaining wires 4 Connect remaining wires to outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements Connect ground wire F green or bare of power supply cord to external groun...

Page 9: ... any screws from a 3 4 19 mm UL listed strain relief UL marking on strain relief Put threaded section of strain relief through hole below terminal block opening screw removable conduit connector onto strain relief threads 1 Attach direct wire strain relief Direct wire strain relief Put direct wire cable through strain relief Strain relief should be a tight fit with dryer cabinet and be in a horizo...

Page 10: ...ion To connect wires to terminal block place hooked end of wire under terminal block screw facing to the right squeeze hooked end together and tighten screw 2 Connect wires to terminal block A 5 Connect ground wire Connect ground wire green or bare F of direct wire cable to external ground conductor screw A Tighten screw F Place hooked ends of remaining direct wire cable wires under outer terminal...

Page 11: ...nd tighten screw 2 Connect wires to terminal block Place hooked end of neutral wire white or center wire C of direct wire cable under center terminal block screw B Squeeze hooked end together Tighten screw 4 Connect neutral wire C B 5 Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws hooks facing right Squeeze hooked ends together and ...

Page 12: ...ible to clean Must be fully extended and supported in final dryer location Remove excess to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install in enclosed walls ceilings or floors The total length should not exceed 7 3 4 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged ...

Page 13: ...er information see Assistance or Service section in your Use and Care Guide PLAN VENT SYSTEM Choose your exhaust installation type Recommended exhaust installation Periscope installation Over the top installation also available with one offset elbow Bottom exhaust installation Special provisions for mobile homes Exhaust vent must be securely fastened to a noncombustible portion of mobile home and ...

Page 14: ...nlet hoses Do not use old hoses Turn cold water off remove and replace rubber washer 1 Turn cold water faucet off and remove washer inlet hose Check and see if rubber washer is in the Y connector Remove old rubber washer from inlet hose and replace with new rubber washer provided Connect vent to exhaust hood 2 Vent must fit over the exhaust hood Secure vent to exhaust hood with 4 102 mm clamp Run ...

Page 15: ...h long hose to dryer fill valve and tighten coupling 5 Attach other end of long hose to fill valve at bottom of dryer back panel Screw on coupling by hand until it is seated on fill valve connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result Turn on cold water faucet 6 Check that the water faucets are turned on Check fo...

Page 16: ... Only Temperature setting If dryer will not start check the following Controls are set in a running or On position Start button has been pushed firmly Dryer is plugged into an outlet and or electrical supply Household fuse is intact and tight or circuit breaker has not tripped Dryer door is closed This dryer automatically runs an installation diagnostic routine at the start of its first cycle NOTE...