7
Power Supply Cord
ELECTRICAL CONNECTION
2.
Remove terminal block cover
Before you start, disconnect power. Remove hold-down screw
and terminal block cover.
Put power supply cord through strain relief. Be sure that wire
insulation on power cord is inside strain relief. Strain relief should
be a tight fit with dryer cabinet and be in a horizontal position.
Do not tighten strain relief screws at this point.
now go to step 1 for 4-wire power supply cord connection
or step 1 for 3-wire power supply cord connection.
Attach power supply cord
to strain relief
2.
Attach power supply cord
strain relief
Remove screws from 3/4" (19 mm) UL listed strain relief (UL
marking on strain relief). Put two clamp section tabs into hole
below terminal block opening with one tab pointing up and one
pointing down. Hold in place and tighten strain relief screws
enough to hold two clamp sections together.
1.
A
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
Power supply cord strain relief: