ELECTRICAL REQUIREMENTS

IMPORTANT: 

The range must be electrically grounded in 

accordance with local codes and ordinances, or in the absence 

of local codes, with the National Electrical Code, ANSI/NFPA 70 

or Canadian Electrical Code, CSA C22.1.

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine that 

the ground path is adequate. 

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit

is required. A time-delay fuse or circuit breaker is also 

recommended. It is recommended that a separate circuit 

serving only this range be provided. 

Electronic ignition systems operate within wide voltage

limits, but proper grounding and polarity are necessary. 

Check that the outlet provides 120-volt power and is 

correctly grounded.

CABINET OPENING DIMENSIONS

Cabinet opening dimensions shown are for 25" (64.0 cm) 

countertop depth, 24" (61.0 cm) base cabinet depth and 36" 

(91.4 cm) countertop height.

IMPORTANT:

 If installing a range hood or microwave hood 

combination above the range, follow the range hood or 

microwave hood combination installation instructions for 

dimensional clearances above the cooktop surface.
Range may be installed next to combustible walls with zero 

clearance.

NOTE:

 When installed in a slide-in cutout, the front of oven 

door may protrude beyond the base cabinet.

*NOTE: 

24" (61.0 cm) minimum when bottom of wood or

metal cabinet is shielded by not less than 

1

4

" (0.64 cm) flame

retardant millboard covered with not less than No. 28 MSG

sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)

aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the

cooking platform and the bottom of an uncovered wood or

metal cabinet.

A.   18" (45.7 cm) upper side cabinet to countertop

B.   13" (33 cm) max. upper cabinet depth

C.   30" (76.2 cm) min. opening width

D.   For minimum clearance to top of cooktop, see NOTE*.

E.   30" (76.2 cm) min. opening width

F.   3" (7.6 cm) min. clearance from both sides of range to side wall or

     other combustible material.

G.  The shaded area is recommended for installation of rigid gas pipe

     and grounded outlet.

H.   13 

1

8

" (33.3 cm)

I.    7 

11

16

" (19.5 cm)

J.   4 

13

16

"" (12.2 cm)

K.   3 

11

16

" (9.4 cm) or measurement of N, whichever is greater

L.  12" (30.5 cm)

M. Cabinet door or hinges should not extend into the cutout.

N.  Remaining counter depth should not exceed 2¼" (5.7 cm)

Page 2 of 2

Because Whirlpool Corporation policy includes a continuous commitment to 

improve our products, we reserve the right to change materials and specifications 

without notice.

Dimensions are for planning purposes only. For complete details, see 

Installation Instructions packed with product. Specifications subject to 

change without notice.

Ref. W10665256

E

0

8

/15

M

A

B

C

D

E

F

H

I

J

L

K

G

N