15
Complete Connection
1.
Check that the gas pressure regulator shut-off valve is in the
“on” position.
A.
Gas pressure regulator shut-off valve shown in the “on” position
2.
Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
3.
Test all connections by brushing on an approved noncorrosive
leak-detection solution. If bubbles appear, a leak is indicated.
Correct any leak found.
4.
Remove cooktop burner caps and bases from package
containing parts. Place the burner bases as indicated by the
following illustration for your model:
For Select Models:
A.
Small (Auxiliary)
B.
Large (Ultra Rapid)
C. Oval (OV)
D. Medium (Semi Rapid)
E.
Wok
NOTE:
Each round burner base is marked with one of the
following: AUX, SR, UR.
5.
Align the gas tube opening in the burner base with the orifice
holder on the cooktop and the igniter electrode with the notch
in the burner base.
A. Burner cap
B. Gas tube opening
C. Burner base
D. Orifice holder
E. Igniter electrode
6.
Place the burner caps on the appropriate burner bases.
IMPORTANT:
The bottom of the small and medium caps are
different. Do not put the wrong size burner cap on the burner
base.
Small cap
(Auxiliary)
Medium cap
(Semi Rapid)
Wok cap
Large cap
(Ultra Rapid)
Burner caps should be level when properly positioned. If
burner caps are not properly positioned, surface burners
willnot light. The burner cap should not rock or wobble when
properly aligned.
A. Incorrect
B. Correct