20
2.
Remove terminal block cover
Before you start, disconnect power. Remove hold-down
screw (B) and terminal block cover (C).
B
C
A
D
A. Center terminal block screw
B. Hold-down screw
C. Terminal block cover
D. External ground conductor screw
Electrical Connection, 24" models (U.S.A. Only)
Power Supply Cord
Direct Wire
Electrical Connection Options
1.
Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to “4-Wire
Power Supply Cord Connection” section.
Then, go to “Venting Requirements.”
3-wire direct connection:
Go to “3-Wire
Direct Wire Connection” section. Then go
to “Venting Requirements.”
4-wire direct connection:
Go to “4-Wire
Direct Wire Connection” section. Then go
to “Venting Requirements.”
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to “3-Wire
Power Supply Cord Connection” section.
Then go to “Venting Requirements.”
NOTE:
If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
3-Wire Connection” section. This connection may be
used with either a power supply cord or a direct wire
connection.
Summary of Contents for WET4027EW1
Page 2: ...2 Washer Dryer Safety ...
Page 3: ...3 ...
Page 34: ...34 Sécurité de la laveuse sécheuse ...
Page 35: ...35 ...
Page 53: ...53 Notes ...
Page 55: ...55 ...
Page 63: ...63 ...
Page 86: ...86 Notas ...
Page 87: ...87 Notas ...