31
Turn on water faucets to check for leaks. A small amount of
water may enter washer. It will drain later.
6.
Check for leaks
Secure drain hose to laundry tub leg, drain standpipe, or inlet
hoses for wall standpipe with shipping strap removed earlier
(27" models) or plastic strap included in the parts package
(24" models).
It is the responsibility of the installer to install and secure the
drain hose into the provided plumbing/drain in a manner that
will avoid the drain hose coming out of or leaking from the
plumbing/drain.
7.
Secure drain hose
4.5"
(113 mm)
4.5"
(113 mm)
4.5"
(113 mm)
4.5"
(113 mm)
4.5"
(113 mm)
Laundry Tub
Standpipe
Wall
Connect Vent
1.
Connect vent to exhaust outlet
(27" model shown)
2.
Move washer/dryer to fi nal location
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fi t over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
Move washer/dryer to fi nal location, taking care not to crush
or kink vent.
After washer/dryer is in place, remove corner posts and
cardboard from under washer/dryer.
Connecting from front
(for closet or recessed
area)
Connecting
from rear
4.5"
(114 mm)
4.5"
(114 mm)
4.5"
(114 mm)
Summary of Contents for WET4027EW1