background image

4

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances. Do 

not obstruct flow of combustion and ventilation air. 

It is the installer’s responsibility to comply with installation 
clearances specified on the model/serial rating plate. The 
model/serial rating plate is located on the left side of the 
bottom of the broiler.

The range should be located for convenient use in the 
kitchen.

Recessed installations must provide complete enclosure of 
the sides and rear of the range.

To eliminate the risk of burns or fire by reaching over heated 
surface units, cabinet storage space located above the 
surface units should be avoided. If cabinet storage is to be 
provided, the risk can be reduced by installing a range hood 
that projects horizontally a minimum of 5" (12.7 cm) beyond 
the bottom of the cabinets.

All openings in the wall or floor where range is to be installed 
must be sealed.

Do not seal the range to the side cabinets.

Cabinet opening dimensions that are shown must be used. 
Given dimensions are minimum clearances.

The anti-tip bracket must be installed. To install the anti-tip 
bracket shipped with the range, see “Install Anti-Tip Bracket” 
section.

Grounded electrical supply is required. See “Electrical 
Requirements” section. 

Proper gas supply connection must be available. See “Gas 
Supply Requirements” section.

Contact a qualified floor covering installer to check that the 
floor covering can withstand at least 200°F (93°C). 

Use an insulated pad or ¼" (0.64 cm) plywood under range if 
installing range over carpeting.

IMPORTANT:

 To avoid damage to your cabinets, check with your 

builder or cabinet supplier to make sure that the materials used 
will not discolor, delaminate or sustain other damage. This oven 
has been designed in accordance with the requirements of UL 
and CSA International and complies with the maximum allowable 
wood cabinet temperatures of 194°F (90°C).

Mobile Home - Additional Installation Requirements

The installation of this range must conform to the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280). When such standard is not 
applicable, use the Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A or with local codes.

Mobile home installations require:

When this range is installed in a mobile home, it must be 
secured to the floor during transit. Any method of securing 
the range is adequate as long as it conforms to the standards 
listed above.

Product Dimensions

A. Model/serial rating plate location

A

A. 36" (91.4 cm)
B. 29

⁷⁄₈

" (75.9 cm)

C. 25

⁷⁄₆₄

" (63.8 cm)

D. 47

⁵⁄₃₂

" (119.8 cm)

D

C

B

A

Summary of Contents for WFG320M0BB

Page 1: ... Install Anti Tip Bracket 7 Make Gas Connection 8 Verify Anti Tip Bracket Is Installed and Engaged 9 Level Range 10 Electronic Ignition System 10 Complete Installation 12 GAS CONVERSIONS 12 LP Gas Conversion 12 Complete Conversion 14 Natural Gas Conversion 14 Complete Conversion 16 W10620413E IMPORTANT Save for local inspector s use Installer Leave installation instructions with the homeowner Home...

Page 2: ... property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cann...

Page 3: ...nge and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage anti tip bracket if range is moved Do not operate range without anti tip bracket installed and engaged Failure to follow these instructions can result in death or serious burns to children and adults Anti Tip Bracket ...

Page 4: ...Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at least 200 F 93 C Use an insulated pad or 0 64 cm plywood under range if installing range over carpeting IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier...

Page 5: ...his range is equipped with a power supply cord having a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a grounded 3 prong outlet Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are necessary Check that the outlet provides 120 volt power and is correctly grounded This range is equipped with an electronic ignition ...

Page 6: ...connector If local codes permit a new CSA design certified 4 to 5 ft 122 to 152 4 cm long 1 3 cm or 1 9 cm I D flexible metal appliance connector may be used for connecting range to the gas supply line A 1 3 cm male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator Do not kink or damage the flexible metal tubing when moving the range M...

Page 7: ...the range to support the range when it is laid on its back 5 Using 2 or more people firmly grasp the range and gently lay it on its back on the cardboard corners 6 Pull cardboard bottom firmly to remove then remove foam support 7 Use an adjustable wrench to loosen the leveling legs Adjust the leveling legs to the correct height Leveling legs can be loosened to add up to a maximum of 1 2 5 cm A min...

Page 8: ...rs see B and F in the following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters being certain not to move or turn the gas pressure regulator 3 Use a combination wrench and an adjustable wrench to attach the flexible connector to the adapters IMPORTANT All connections must be wrench tightened Do not make connection...

Page 9: ...ositioned If burner caps are not properly positioned surface burners will not light Place burners burner caps and grates on the cooktop 6 Plug into a grounded 3 prong outlet VerifyAnti TipBracketIsInstalledand Engaged 1 Place the outside of your foot against the bottom front of the broiler and grasp the lower right or left side of the control panel as shown NOTE If your countertop is mounted with ...

Page 10: ... Place a standard flat rack in oven 2 Place level on the rack and check levelness of the range first side to side then front to back 3 If range is not level pull range forward until rear leveling leg is removed from the anti tip bracket 4 Use a drive ratchet and slip joint pliers to adjust leveling legs up or down until the range is level 5 Push range back into position 6 Check that rear leveling ...

Page 11: ...25 will appear in the display The BROIL indicator will light 2 Press the START ENTER pad The oven burner should light in 20 40 seconds this delay is normal The oven valve requires a certain time before it will open and allow gas to flow To avoid damaging the hot surface igniter do not insert any object into the openings of the shield that surrounds the igniter or clean that area 3 Check the oven b...

Page 12: ... gas supply line shutoff valve is open press the CANCEL button on the oven control panel and contact a qualified technician If you need Assistance or Service Please reference the Assistance or Service section of the Use and Care Guide or the cover of the User Instructions or contact the dealer from whom you purchased your range GAS CONVERSIONS Gas conversions from Natural gas to LP gas or from LP ...

Page 13: ...w by hand turn it over and screw it in again 4 Reinstall the cap To Convert Surface Burners 1 Remove burner grate burner caps and burners 2 Locate LP gas orifice spuds for top burners in the bag containing literature included with the range One LP gas spud is stamped 88 Yellow Black two are stamped 116 Yellow Orange and one is stamped 70 Yellow White 3 Remove Natural gas orifice spuds using a 7 mm...

Page 14: ...n for proper burner ingestion operation and burner flame adjustments IMPORTANT You may have to adjust the LOW setting for each cooktop burner Checking for proper cooktop and oven burner flames is very important The small inner cone should have a very distinct blue flame to 0 64 cm to 1 3 cm long The outer cone is not as distinct as the inner cone LP gas flames have a slightly yellow tip 4 Close th...

Page 15: ...and turn it over and screw it in again 4 Reinstall the cap To Convert Surface Burners 1 Remove burner grate burner caps and burners 2 Locate the Natural gas orifice spuds for top burners in the bag containing literature included with the range Two Natural gas spuds are stamped 194 Black White one is stamped 155 Red Brown and one is stamped 110 Red Brass 3 Remove the LP gas orifice spuds using a 7 ...

Page 16: ...s oven tray and flame spreader CompleteConversion 1 Refer to the Make Gas Connection section for properly connecting the range to the gas supply 2 Turn the manual shutoff valve in the gas supply line to the open position 3 Refer to the Electronic Ignition System section for proper burner ingestion operation and burner flame adjustments IMPORTANT You may have to adjust the LOW setting for each cook...