14
7.
Reassemble the inner and outer door assemblies with the
6 screws.
Reverse the strike
1.
Use a small flat-blade screwdriver to remove plug strip from
the dryer door opening. Slide the head of the screwdriver
under the plugs, being certain not to scratch the dryer
surface. Lift up.
2.
Remove the strike.
3.
Insert strike and plug strip on the opposite side.
Reinstall the door
1.
Reattach door to dryer front panel with the 4 screws.
2.
Check for fingerprints on the glass. Clean the glass if
necessary.
3.
Close door and check that it latches securely.
Complete Installation
1.
Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2.
Check that you have all of your tools.
3.
Dispose of/recycle all packaging materials.
4.
Check the dryer’s final location. Be sure the vent is not
crushed or kinked.
5.
Check that the dryer is level. See “Level Dryer.”
6.
Plug into a grounded 3 prong outlet. Turn on power.
7.
Remove any protective film or tape remaining on the dryer.
8.
Read “Dryer Use.”
9.
Wipe the dryer drum interior thoroughly with a damp cloth to
remove any dust.
10.
Select a Timed Dry heated cycle, and start the dryer. Do not
select the Air Only Temperature setting.
If the dryer will not start, check the following:
■
Dryer is plugged into a grounded 3 prong outlet.
■
Electrical supply is connected.
■
Household fuse is intact and tight, or circuit breaker has
not tripped.
■
Dryer door is closed.
11.
When the dryer has been running for 5 minutes, open the
dryer door and feel for heat. If you feel heat, cancel cycle and
close door. If you do not feel heat, turn off the dryer and
check that the gas supply line shutoff valve is open.
■
If the gas supply line shutoff valve is closed, open it, then
repeat the 5-minute test as outlined above.
■
If the gas supply line shutoff valve is open, contact a
qualified technician.
A. Plug strip (cannot be seen from this angle)
B. Door strike
A. Dryer front panel
B. Door assembly
B
A
A
B
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING