TrOUbLeSHOOTING
Try these solutions to possibly avoid costs of a service call...
Dryer Operation
Dryer will not run:
n
Has a household fuse blown, or has a circuit breaker
tripped?
Electric dryers use 2 household fuses or circuit
breakers. Check that both fuses are intact and tight, and
breakers have not tripped. Replace fuse or reset circuit
breaker. If problem persists, call an electrician.
Dryer drum turns, but no heat:
n
Has a household fuse blown, or has a circuit breaker
tripped?
Electric dryers use 2 household fuses or circuit
breakers. Replace fuse or reset circuit breaker. If problem
persists, call an electrician.
Dryer displaying code message:
n
“PF” (power failure) Check the following:
Was drying cycle
interrupted by power failure? Press and hold START to restart
dryer.
Try the following:
Check if a household fuse has blown or circuit breaker has
tripped. Electric dryers use two household fuses or breakers.
Replace fuse or reset circuit breaker.
Confirm power cord is properly installed. Refer to “Electrical
Connection” section for details.
Select a Timed Dry heated cycle, and restart dryer.
If message persists, consult a qualified electrician.
n
For all models without a display window, if “WET”
indicator light is flashing and all other display/indicator
lights on control panel are off:
Call for service.
n
“F” Variable (F1E1, F2E2, F3E1, F3E2, F7E1, F3E6, F3E7)
service codes:
Call for service.
Dryer Results
Clothes are not drying satisfactorily, drying times are
too long, or load is too hot:
n
Is lint screen clogged with lint?
Lint screen should be
cleaned before each load.
n
Is exhaust vent or outside exhaust hood clogged with lint,
restricting air movement?
Run dryer for 5-10 minutes. Hold
hand under outside exhaust hood to check air movement. If
you do not feel air movement, clean exhaust system of lint or
replace exhaust vent with heavy metal or flexible metal vent.
n
Are fabric softener sheets blocking grille?
Use only one
fabric softener sheet, and use each only once.
n
Is exhaust vent correct length?
Check if exhaust vent is too
long or has too many turns. Long venting increases dry time.
n
Is correct power supply available?
Electric dryers require
240-volt power supply. Check with a qualified electrician.
n
Was a regular fuse used?
Use a time-delay fuse.
q
Check that dryer is level. See “Level Dryer”.
q
Remove blue film on console and any tape remaining on
dryer.
q
Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
q
Read “Dryer Use” in your Use and Care Guide.
q
Plug into a grounded outlet.
q
Check that gas supply is on.
q
Check for leaks.
All Models:
q
Select a Timed Dry heated cycle, and start dryer. Do not
select Air Only Temperature setting.
If dryer will not start, check the following:
• Controls are set in a running or “On” position.
• Start button has been pushed firmly.
• Dryer is plugged into an outlet and/or electrical supply is
connected.
• Household fuse is intact and tight, or circuit breaker has not
tripped.
• Dryer door is closed.
This dryer automatically runs an installation diagnostic routine
at the start of its first cycle.
NOTE:
You may notice an odor when dryer is first heated. This
odor is common when heating element is first used. The odor
will go away.
Electric Models Only:
Gas Models Only:
DOOr reVerSaL
If you prefer to reverse the door swing on your dryer:
n
A door reversal kit, Part Number W10277499 is available
to order. For further information, see “Assistance or Service”