Gas Dryer
PRODUCT MODEL NUMBERS
WGD94HEX, WGD95HEX, WGD97HEX
NOTE:
Most installations require a minimum 5" (102 mm)
clearance behind the dryer for the exhaust vent with elbow.
See “Venting Requirements”.
27"
(686 mm)
3
/
4
"*
(18 mm)
38
1
/
8
"
(968 mm)
Back view:
6
1
/
4
"
(159 mm)
29
7
/
8
"*
(759 mm)
3
1
/
2
"*
(89 mm)
5
3
/
4
"*
(146 mm)
6
1
/
8
"*
(156 mm)
14
3
/
8
"
(365 mm)
25
3
/
4
"
(654 mm)
3
/
4
"*
(18 mm)
* Approx. measurement
Side view:
Front view:
Gas
Water
Vent
Installation spacing for recessed area
or closet installation
All dimensions show recommended and minimum spacing allowed.
■
Additional spacing should be considered for ease of
installation and servicing.
■
Additional clearances might be required for wall, door, floor moldings, dryer venting, and gas line.
■
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered
doors with equivalent ventilitation openings are acceptable.
■
Companion appliance spacing should also be considered.
18" min.
(457 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
2
min.
(155 cm
2
)
48 in.
2
min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
Recommended installation clearances (dryer only):