4
A. 5,000 BTUs: 22" (550 mm) minimum
B. 5,000 BTUs: 14
½
" (368 mm) minimum
Window Installation
Window Opening Measurements:
■
22" (550 mm) minimum to 35" (914 mm) maximum
opening width
■
14
½
" (368 mm) minimum opening height
Electrical Requirements
■
115 volts (103.5 min. - 126.5 max.)
■
0-12 amps
■
15-amp time-delay fuse or circuit-breaker
■
If there is a “Single Circuit Only” label on the unit,
use on a dedicated single-outlet circuit only. If a
dedicated single-outlet circuit is not available, then
it is the customer’s responsibility to have a single-
outlet circuit installed by a qualified electrician.
■
If there is no “Single Circuit Only” label on the
unit, the unit may be used on any branch circuit
of correct voltage and adequate current
protection rating.
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating
outlet is not available, it is the customer’s responsibility to have
a properly grounded 3 prong outlet installed by a qualified
electrical installer. It is the customer’s responsibility:
■
To contact a qualified electrical installer.
■
To assure that the electrical installation is adequate and
in conformance with National Electrical Code, ANSI/NFPA
70—latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
Power Supply Cord
NOTE:
Your air conditioner’s power supply cord may differ from
the one shown.
This room air conditioner is equipped with a power supply cord
required by UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is crushed,
the electronics detect leakage current and power will be
disconnected in a fraction of a second.
Electrical Requirements—All Models
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the air conditioner
cabinet.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
�re, or electrical shock.
WARNING
A
B
A. Test button
B. Reset button
A
B
95114_Whirlpool_Mechanical_AC_book.indb 4
12/16/2016 11:59:25 AM