19
Heat Pump—2-Stage Emergency Heat and 2-Stage Auxiliary Heat—1 Outdoor Thermostat
NOTES:
■
1
st
Stage auxiliary heat enabled by room thermostat.
■
2
nd
Stage auxiliary heat enabled by room thermostat and
outdoor thermostat.
1. Y enables high speed fan cooling.
2. E enables low speed fan heating. W2 enables low speed fan
heating. W2 with OT2 closed enables high speed fan heating.
3. OT2 PJ2 must be cut for this configuration.
4. Cut HUM PJ6 jumper if using humidistat. Humidistat opens
on humidity rise.
5. DIP Switch 4 must be in the “OFF” position.
Heat Pump—2-Stage Emergency Heat and 1-Stage Auxiliary Heat—1 Outdoor Thermostat
NOTES:
■
No auxiliary heat in heat pump mode until outdoor thermostat
closes.
1. Y enables high speed fan cooling.
2. E enables low speed fan heating. W2 with OT2 closed
enables high speed fan heating.
3. OT1 PJ4 must be cut for this configuration.
4. OT2 PJ2 must be cut for this configuration.
5. Cut HUM PJ6 jumper if using humidistat. Humidistat opens
on humidity rise.
6. DIP Switch 4 must be in the “OFF” position.
Goodman 6 Long
HIGH VOLTAGE!
WARNING
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage, personal injury or death.
2-Speed Heat Pump
2
nd
Stage Heater
Humidistat
(Optional)
Room Thermostat
1
st
Stage Heater
See Note 4
Remove
Production
Wire Y1-O
See Note 4
Please refer
to manual
for proper
DIP switch (CFM)
configuration.
See Note 3
If Needed
Outdoor Thermostat
2-Speed Heat Pump
2
nd
Stage Heater
Humidistat
(Optional)
Room Thermostat
1
st
Stage Heater
See Note 5
Remove
Production
Wire Y1-O
See Note 4
Please refer
to manual
for proper
DIP switch (CFM)
configuration.
See Note 3
If Needed
See Note 5
Outdoor Thermostat