background image

FURNACE USER INSTRUCTIONS

FOR PACKAGE GAS ELECTRIC UNITS

GAS FURNACE SAFETY

Recognize this symbol as a safety precaution.

Table of Contents

GAS FURNACE SAFETY................................................................1

IMPORTANT NOTE TO THE OWNER REGARDING 
PRODUCT WARRANTY .................................................................2

UNIT LOCATION.............................................................................2

UNIT INSTALLATION .....................................................................3

AIR REQUIREMENTS.....................................................................3

THERMOSTAT ................................................................................4

PROPANE (LP) GAS INSTALLATIONS ONLY..............................4

OPERATING INSTRUCTIONS .......................................................4

Heating Start-Up ..........................................................................4
Heating Shutdown .......................................................................5
Cooling Operation ........................................................................5

SAFETY CIRCUITS.........................................................................5

Secondary Limit Control ..............................................................5

Rollout Limit Control.....................................................................6
Compressor Protection Devices ..................................................6
Short-Cycle Protector ..................................................................6
Igniter............................................................................................6
Induced Draft Blower ...................................................................6
Indoor Air Circulator Blower.........................................................6

ROUTINE MAINTENANCE.............................................................6

Annual Inspection.........................................................................6
Replacing or Cleaning the Filter...................................................7
Clean Outside Coil—Qualified Servicer Only...............................7
Condenser, Evaporator and Induced Draft Motors .....................7
Compressor..................................................................................7

SAFETY LABELS ............................................................................8

ASSISTANCE OR SERVICE ...........................................................8

WPHI-116B

Tradewinds Distributing Company

14610 Breakers Drive

Jacksonville, FL  32258

Installer: Affix this manual, 
Installation Instructions and 
Warranty adjacent to appliance.

Owner: Read and keep all 
product literature in a safe place 
for future reference.

PLACEHOLDER
FOR
BAR
CODE

If the information in these instructions is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.

— Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone 

in your building.

• Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire 

department.

— Installation and service must be performed by a 

qualified installer, service agency or the gas supplier.

WARNING

Hazards or unsafe practices could result in property
damage, product damage, severe personal injury or death. 

Hazards or unsafe practices may result in property
damage, product damage, personal injury or death. 

WARNING

CAUTION

Should overheating occur or the gas supply fail to shut
off, turn off the manual gas shutoff valve external to the
furnace before turning off the electrical supply.

WARNING

To avoid property damage, personal injury or death, do 
not use this furnace if any part of the furnace has been 
under water. Immediately call a qualified service technician 
to inspect the furnace and to replace any part of the 
control system and any gas control having been under 
water.

WARNING

Summary of Contents for WPHI-116B

Page 1: ...tructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supp...

Page 2: ...ine or fluorine as they could corrode the heat exchanger If you need further information on this subject contact your installing dealer or another qualified servicer Familiarize yourself with the controls that turn off the gas and electrical power to the unit Establish a regular service and maintenance schedule to ensure efficient and safe operation of the unit The unit must be placed where no run...

Page 3: ...ial Warning for Installation of Furnace or Air Handling Units in Enclosed Areas such as Garages Utility Rooms or Parking Areas Carbon monoxide producing devices such as an automobile space heater gas water heater etc should not be operated in enclosed areas such as unventilated garages utility rooms or parking areas because of the danger of carbon monoxide CO poisoning resulting from the exhaust e...

Page 4: ...emove the heat exchanger door on the side of the unit by removing the screws 5 This unit is equipped with an ignition device which automatically lights the burner NOTE Do not try to light the burner by hand 6 Move the gas control switch to the OFF position NOTE Do not use excessive force 7 Wait 5 minutes to clear out any gas Then check for a gas odor including near the floor as some types of gas a...

Page 5: ...be delayed by the short cycle protector feature of the ignition control board Check the manual reset devices on the rollout limit switch as described in this manual Gas Control Valve White Rodgers 36G22 Gas Control Valve Honeywell Model VR8215 Single Stage SAFETY CIRCUITS A number of safety circuits are employed to ensure safe and proper unit operation These circuits serve to control any potential...

Page 6: ...tion products IndoorAirCirculatorBlower Keep the blower access door panel in place except for inspection and maintenance ROUTINE MAINTENANCE If you perform maintenance on the unit yourself remember that certain mechanical and electrical knowledge skills and tools are required to perform unit maintenance Personal injury or death may result If you are not properly trained You should call your instal...

Page 7: ...side air flowing over it should be inspected annually and cleaned as frequently as necessary to keep the finned areas free of leaves grass seeds and debris Condenser EvaporatorandInducedDraftMotors Bearings on the air circulating blower motor condenser motor and the combustion fan motor are permanently lubricated No additional oiling is required Compressor The compressor motor is hermetically seal...

Page 8: ...ocal codes In the absence of local codes follow the National Fuel Gas Code ANSI Z223 1 OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you then smell gas STOP Follow B in the safety information ...

Reviews: