FURNACE USER INSTRUCTIONS
FOR PACKAGE GAS ELECTRIC UNITS
GAS FURNACE SAFETY
Recognize this symbol as a safety precaution.
Table of Contents
GAS FURNACE SAFETY................................................................1
IMPORTANT NOTE TO THE OWNER REGARDING
PRODUCT WARRANTY .................................................................2
UNIT LOCATION.............................................................................2
UNIT INSTALLATION .....................................................................3
AIR REQUIREMENTS.....................................................................3
THERMOSTAT ................................................................................4
PROPANE (LP) GAS INSTALLATIONS ONLY..............................4
OPERATING INSTRUCTIONS .......................................................4
Heating Start-Up ..........................................................................4
Heating Shutdown .......................................................................5
Cooling Operation ........................................................................5
SAFETY CIRCUITS.........................................................................5
Secondary Limit Control ..............................................................5
Rollout Limit Control.....................................................................6
Compressor Protection Devices ..................................................6
Short-Cycle Protector ..................................................................6
Igniter............................................................................................6
Induced Draft Blower ...................................................................6
Indoor Air Circulator Blower.........................................................6
ROUTINE MAINTENANCE.............................................................6
Annual Inspection.........................................................................6
Replacing or Cleaning the Filter...................................................7
Clean Outside Coil—Qualified Servicer Only...............................7
Condenser, Evaporator and Induced Draft Motors .....................7
Compressor..................................................................................7
SAFETY LABELS ............................................................................8
ASSISTANCE OR SERVICE ...........................................................8
WPHI-116B
Tradewinds Distributing Company
14610 Breakers Drive
Jacksonville, FL 32258
Installer: Affix this manual,
Installation Instructions and
Warranty adjacent to appliance.
Owner: Read and keep all
product literature in a safe place
for future reference.
PLACEHOLDER
FOR
BAR
CODE
If the information in these instructions is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
WARNING
Hazards or unsafe practices could result in property
damage, product damage, severe personal injury or death.
Hazards or unsafe practices may result in property
damage, product damage, personal injury or death.
WARNING
CAUTION
Should overheating occur or the gas supply fail to shut
off, turn off the manual gas shutoff valve external to the
furnace before turning off the electrical supply.
WARNING
To avoid property damage, personal injury or death, do
not use this furnace if any part of the furnace has been
under water. Immediately call a qualified service technician
to inspect the furnace and to replace any part of the
control system and any gas control having been under
water.
WARNING