5

For the most efficient and quiet operation:

Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent 

between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps or duct tape to seal all joints in the vent system.
The vent system must have a damper. If roof or wall cap has a 

damper, do not use damper supplied with the range hood.
Use caulking to seal exterior wall or roof opening around the 

cap.

Calculating Vent System Length

To calculate the length of the system you need, add the 

equivalent feet (meters) for each vent piece used in the system. 

Electrical Requirements

Observe all governing codes and ordinances. 

Ensure that the electrical installation is adequate and in 

conformance with National Electrical Code, ANSI/NFPA 70 (latest 

edition), or CSA Standards C22.1-94, Canadian Electrical Code, 

Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes 

and ordinances.

If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that the 

ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 

required.
If the house has aluminum wiring, follow the procedure 

below:
1. Connect a section of solid copper wire to the pigtail

leads.

2. Connect the aluminum wiring to the added section of

copper wire using special connectors and/or tools 

designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended 

procedure. Aluminum/copper connection must conform with 

local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of 

the appliance as specified on the model/serial rating plate. 

The model/serial plate is located behind the filter on the rear 

wall of the range hood.
Wire sizes must conform to the requirements of the National 

Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 

Standards C22. 1-94, Canadian Electrical Code, Part 1 and 

C22.2 No. 0-M91 (latest edition) and all local codes and 

ordinances.

Vent System

Vent Piece

45° elbow

2.5 ft (0.8 m)

90° elbow

5 ft (1.5 m)

7" (17.8 cm) wall cap

0 ft (0 m)

Example vent system

1 - 90° elbow

= 5 ft (1.5 m)

1 - wall cap

= 0 ft (0 m)

8 ft (2.4 m) straight

= 8 ft (2.4 m)

System length

= 13 ft (3.9 m)

Maximum Recommended Length

7" (17.8 cm) Round Vent

= 50 ft (15.2 m)

Wall cap

90˚ elbow

2 ft (0.6 m)

6 ft (1.8 m)

Summary of Contents for WVU17UC0JB

Page 1: ...POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT LIB0159236A W11367653B You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others ar...

Page 2: ...When cutting or drilling into wall or ceiling do not damage electrical wiring and other utilities Ducted fans must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings atti...

Page 3: ...ed recirculating require charcoal filters See the Assistance or Service section for information on ordering charcoal filters For Mobile Home Installations The installation of this range hood must conform to the Manufactured Home Construction Safety Standards Title 24 CFR Part 328 formerly the Federal Standard for Mobile Home Construction and Safety title 24 HUD Part 280 or when such standard is no...

Page 4: ...nate the vent system in an attic or other enclosed area Do not use a 4 10 2 cm laundry type wall cap Use 7 17 8 cm round metal vent Rigid metal vent is recommended Plastic or metal foil vent is not recommended The length of vent system and number of elbows should be kept to a minimum to provide efficient performance A 24 61 0 cm minimum distance from electric cooking surface 24 61 0 cm minimum dis...

Page 5: ...erymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and or too...

Page 6: ... anchors Using 8 18 x 1 4 2 x 25 mm flat head 2 Phillips screws install the mounting brackets using the upper holes NOTE For installations to a surface other than drywall it is recommended that a qualified contractor determine the anchoring method 5 Prepare Range Hood 4 Remove Grease Filters Set the range hood on its back on a covered surface Remove the two filter security screws and put them asid...

Page 7: ...17 8 cm round vent mounting plate draw the vent opening outline on the underside of the cabinet Place the vent mounting plate on the bottom of the cabinet Position the edge of the plate with the widest distance A between the hole and edge of the mounting plate against the wall Position the side edges of the mounting plate between the dots marked previously IMPORTANT The widest edge A of the vent m...

Page 8: ...ab holes Non vent Recirculating Installations Using a 2 Phillips screwdriver remove the 2 screws and remove the top front rectangular vent cover E Go to Step 12 7 17 8 cm Round Vent Installations Remove both top knockouts C and D 10 Attach Vent Damper or Transition 7 17 8 cm Round Vent Mounting Plate Using 2 short Phillips head screws install the 7 17 8 cm round vent mounting plate over the vent k...

Page 9: ... the green or bare ground wire C from the power supply to the green ground screw in the electrical box and tighten the screw securely Reinstall the electrical box cover Reconnect power Option 2 Power Cord Kit Installations For optional power cord kit installations follow the instructions supplied with the power cord kit See the Assistance or Service section for information on ordering NOTE Use onl...

Page 10: ...To Clean the Filter 1 Remove the screw from the grease filter retainer 2 Push the grease filter retainer to release the filter 3 For vented installations Grease filters should be cleaned To Replace the Filter 1 To reinstall the filter place the back edge of the filter into the channel at the rear of the hood Push the filter into place and turn the filter retainer to secure the filter to the range ...

Page 11: ...rate make sure the light bulb is inserted correctly before calling service WIRING DIAGRAM BK For ADA compliance add these elements during the installation Remote Switch Light Switch Off On C25 SEL0157858A L G Ground Screw Forsupplyconnection usewiressuitablefor atleast75 167 F L N E26 LED BULB BK WH BK BR BK RD BR WH RD WH WH BK Speed 2 Common WH Speed 1 RD Motor Switch Low Off High Motor characte...

Page 12: ...alers Installation information Use and maintenance procedures Accessory and repair parts sales Specialized customer assistance Spanish speaking hearing impaired limited vision etc For further assistance If you need further assistance you can write to Whirlpool with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Pl...

Page 13: ...as de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiel...

Page 14: ... et évacuer adéquatement les gaz veiller à acheminer l air aspiré par un conduit jusqu à l extérieur ne pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA C...

Page 15: ...a hotte de cuisinière à distance de toute zone exposée à des courants d air comme fenêtres portes et bouches de chauffage à fort débit Respecter les dimensions indiquées pour les ouvertures à découper dans les meubles Ces dimensions tiennent compte des valeurs minimales des dégagements de séparation Avant d effectuer des découpages consulter les instructions d installation fournies par le fabrican...

Page 16: ... de la maison à l extérieur Le clapet anti retour doit être placé du côté air froid de la résistance thermique L élément d isolation thermique doit être aussi proche que possible de l endroit où le circuit d évacuation s introduit dans la partie chauffée de la maison Exigences concernant l évacuation Le circuit d évacuation doit décharger l air à l extérieur excepté pour les installations sans déc...

Page 17: ... 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 L appareil doit être alimenté par un circuit de 120 V CA seulement 60 Hz 15 ampères protégé par fusible Si le domicile possède un câblage en aluminium suivre la procédure ci dessous 1 Raccorder une section de câble en cuivre massif aux conducteurs en queue de cochon 2 Connecter le câb...

Page 18: ...otte Placer la hotte en appui sur la face arrière sur une surface couverte À l aide d un tournevis Phillips n 2 retirer le clapet rectangulaire attaché avec des vis de 3 5 x 9 5 mm À l aide d un tournevis Phillips n 2 retirer le couvercle du boîtier de raccordement A l aide d un tournevis à lame plate retirer l opercule pour le passage de l alimentation électrique approprié 2 Marquage de l emplace...

Page 19: ... montage du conduit circulaire de 7 17 8 cm marquer le tracé de l ouverture d évacuation sur la face inférieure du placard Placer la plaque de montage de conduit sur le fond du placard Positionner contre le mur le bord de la plaque de montage comportant la plus grande distance A entre le trou et le bord de la plaque Positionner les bords latéraux de la plaque de montage entre les trous marqués pré...

Page 20: ...vis à l aide d un tournevis Phillips n 2 et retirer le couvercle rectangulaire avant supérieur E Passer à l étape 12 Installations d évacuation pour conduit circulaire de 7 17 8 cm Retirer les deux opercules supérieurs C et D 10 Fixation du clapet anti reflux ou du raccord de transition Plaque de montage de conduit circulaire de 7 17 8 cm À l aide de 2 vis courtes à tête Phillips installer la plaq...

Page 21: ...tionne pas vérifier que le coupe circuit ne s est pas déclenché et qu aucun fusible n est grillé Déconnecter la source de courant électrique et inspecter les connexions du câblage REMARQUE Pour pouvoir tirer le plus grand parti de la nouvelle hotte de cuisinière lire la section Utilisation de la hotte A B C AVERTISSEMENT Risque d incendie Relier le ventilateur à la terre Utiliser du fil en cuivre ...

Page 22: ...1371717 RTANT Ne pas utiliser de tampons de récurage savonneux de nettoyants abrasifs de crème à polir pour table de cuisson de laine d acier de chiffons de lavage rugueux ou d essuie tout Pour éviter d endommager les surfaces en acier inoxydable ne pas utiliser de nettoyants contenant du chlore Méthode de nettoyage Détergent liquide ou nettoyant tout usage Rincer à l eau propre et sécher avec un ...

Page 23: ...mpoule est correctement insérée dans sa douille avant de demander l intervention d un dépanneur SCHÉMA DE CÂBLAGE 23 N Pour la conformité ADA ajoutezces élements lors de Iínstallation Interrupteur á distance Interrupteur de lumiére Marche Arrêt C25 SEL0157858A Terre Ph Ph Neu Vis de terre Pourapprovisionnerlaconnection utilisezdescablesappropiés pouraumoins75 C 167 F AMPULE Á LED E26 N BL N MAR N ...

Page 24: ...z notre site web à www whirlpool ca Nos consultants vous renseigneront sur les sujets suivants Programmation d une intervention de dépannage Les techniciens de service désignés par Whirlpool sont formés pour remplir la garantie des produits et fournir un service après garantie partout au Canada Caractéristiques et spécifications sur toute notre gamme d appareils électroménagers Références aux conce...

Reviews: