background image

10

2. 

Secure the bottom of the duct with (2) 4.2 x 8 mm screws.

Complete Installation

1. 

For non-vented (recirculating) installations only, install 

charcoal filters over metal grease filter. See the “Range 

Hood Care” section.

2. 

Install metal filters. See the “Range Hood Care” section.

3. 

Check the operation of the range hood blower and light. 

See the “Range Hood Use” section.

NOTE: 

To get the most efficient use from your new range hood, 

read the “Range Hood Use” section.

RANGE HOOD USE

The range hood is designed to remove smoke, cooking 

vapors and odors from the cooktop area. For best results, 

start the hood before cooking and allow it to operate several 

minutes after the cooking is complete to clear all smoke and 

odors from the kitchen.
The hood controls are located on the front side of the canopy.

Range Hood Controls

Operating the LED task light

The On/Off light button controls both lights. Press once 

for on and again for off.

Operating the blower

The Blower Speed buttons turn the blower on and control the 

blower speed and sound level for quiet operation. The speed 

can be changed anytime during fan operation by pressing the 

desired Blower Speed button.
The Blower Off button turns the blower off.

Operating the Ambient Lighting

The switch controls the ambient lighting.

1. 

Press to the left to turn Auto On.

2. 

Press to the right to turn Ambient Lighting On.

3. 

Press to the center to turn Ambient Lighting or Auto Off.

NOTE:

 When the Ambient Lighting is placed in the Auto setting, 

a sensor will automatically sense if it is dark in the area around 

the range hood. The Ambient Lighting will turn on and stay on  

until it senses there is enough light in the area around the range 

hood, or the Ambient Lighting switch is placed in the on or 

off position.

A

B

C

D

E

F

G

H

A.  Louver holes (non-vented 

[recirculating] installations only)

B.  Duct cover
C.  Control panel
D.  Light switch (ambient lighting)

E.  Glass canopy
F.  Perimetric cover
G. LED lights
H.  Metal grease filters (located 

behind the perimetric cover)

A

B

C

D

E

A.  Blower speed maximum button 
B.  Blower speed medium button 
C.  Blower speed minimum button
D.  Blower off button
E.  On/Off LED task light button

Summary of Contents for WVWA5UC6HN0

Page 1: ...bsite at www whirlpool ca HOTTE DE CUISINIÈRE À MONTAGE MURAL DE 30 ET 36 76 2 ET 91 4 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composer le 1 800 807 6777 ou visiter notre site Web à www whirlpool ca Table of Contents Table des matières 2 LIB0098810D W11134239B IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL U...

Page 2: ...ntains one or more chemicals known to the State of California to cause birth defects or other reproductive harm RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Page 4: ...es Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimens...

Page 5: ...r enclosed area Do not use 4 10 2 cm laundry type wall cap Use metal vent only Rigid metal vent is recommended Plastic or metal foil vent is not recommended The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the Most Efficient and Quiet Operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent b...

Page 6: ...s Ensure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A...

Page 7: ...ng used 6 For wood install 2 5 x 45 mm mounting screws Leave a 1 4 6 4 mm gap between the wall and the back of the screw head to slide range hood into place For wall anchors install the 10 x 60 mm wall anchors and install the 5 4 x 75 mm screws into the wall anchors Tighten until the wall anchors are secure Back the screws out 1 4 6 4 mm Vent Cover Bracket Installation 7 Attach vent cover bracket ...

Page 8: ...Use the optional wall anchors if needed ConnectVent System 1 Install transition on top of hood if removed for shipping with 2 3 5 x 9 5 mm sheet metal screws For vented installations only 1 Fit vent system over the exhaust outlet 2 Seal connection with clamps 3 Check that back draft dampers work properly For non vented recirculating installation only 1 Assemble the air deflector with the duct cove...

Page 9: ...nformation on ordering NOTE Use only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood InstallVent Covers 1 When using both upper and lower vent covers push lower cover down onto hood and lift upper cover to ceiling and install with two 4 2 x 8 mm screws NOTE For vented installations the upper vent cover may be reversed to hide...

Page 10: ...urn the blower on and control the blower speed and sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired Blower Speed button The Blower Off button turns the blower off Operating the Ambient Lighting The switch controls the ambient lighting 1 Press to the left to turn Auto On 2 Press to the right to turn Ambient Lighting On 3 Press to the cent...

Page 11: ...washer or hot detergent solution 4 Reinstall the filter by making sure the spring release handles are toward the front Insert aluminum filter into upper track 5 Push in spring release handle 6 Push up on metal filter and release handle to latch into place Non Vented recirculating Installation Filters The charcoal filter is not washable It should last up to 6 months with normal use Replace with Cha...

Page 12: ... Temp Light Sensor Turns on at 10 LUX Turns off at 50 LUX Output Input P1 P2 P4 P3 Driver Output 700mA 2 15 VDC Input 120 VAC Strip LED Ambient Light Switch Function On Off Auto Position Position 3 Position 2 Position 1 3 2 1 3 3 2 2 M N Input 120 VAC Output 700mA 2 15 VDC Driver L N G BK WH YL GN RD WH BU BK BR YL 2 1 L 3 M La POS 1 POS 2 POS 3 1 2 3 BU WH RD BR WH YL BK RD WH YL GN YL GN WH RD B...

Page 13: ...rlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada Customer eXperience Centre toll free 1 800 807 6777 or visit our website at www whirlpool ca Our Consultants Provide Assistance With Scheduling of ...

Page 14: ... use of non genuine Whirlpool parts or accessories 6 Conversion of your product from natural gas or L P gas or reversal of appliance doors 7 Damage from accident misuse abuse fire floods acts of God or use with products not approved by Whirlpool 8 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or modification of the appliance 9 Cosmetic d...

Page 15: ...ièces ou accessoires Whirlpool non authentiques 6 Conversion de votre produit du gaz naturel ou du gaz de pétrole liquéfié ou inversion des portes de l appareil 7 Dommages causés par accident mésusage abus incendie inondations catastrophe naturelle ou l utilisation de produits non approuvés par Whirlpool 8 Réparations aux pièces ou systèmes dans le but de rectifier un dommage ou des défauts résult...