Make Electrical Connection

1.

Disconnect power.

2.

Remove terminal box cover.

3.

Remove the knockout in the terminal box and install

a UL Listed or CSA approved 1/2" (12.7 mm) strain relief.

4.

Run home power supply cable through strain relief

into terminal box.

5.

Use UL Listed wire connectors and connect

black wires (C) together.

6.

Use UL Listed wire connectors and connect

white wires (E) together.

7.

Connect green (or bare) ground wire from home power

supply to yellow-green ground wire (F) in terminal box

using UL Listed wire connectors.

8.

Tighten strain relief screw.

9.

Install terminal box cover.

10.

Check that all light bulbs are secure in their sockets.

11.

Reconnect power.

Optional Power Cord Kit Installations

For optional power cord kit installations, follow the instructions 

supplied with the power cord kit. See the “Assistance or 

Service” section for information on ordering.

NOTE:

 Use only with range hood cord connection kits that have 

been investigated and found acceptable for use with this model 

range hood.

Install Vent Covers

1.

When using both upper and lower vent covers, push lower

cover down onto hood and lift upper cover to ceiling and

install with two 4.2 x 8 mm screws.

NOTE:

 For vented installations, the upper vent cover 

may be reversed to hide slots.

WARNING

Electrical Shock Hazard

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

A

C

B

A. Knockout
B. Terminal box
C. Terminal box cover

A

B

C

D

E

F

A. Home power supply cable
B. UL Listed or CSA

approved strain relief

C. Black wires

D. UL Listed wire connectors
E. White wires
F. Green (or bare) and

yellow-green ground wires

WARNING

Electrical Shock Hazard

Electrically ground blower.
Connect ground wire to green and yellow ground wire 

in terminal box.
Failure to do so can result in death or electrical shock.

C

A

B

A. Bracket
B. 4.2 x 8 mm screws
C. Vent cover

Summary of Contents for WVWA5UC6HN0

Page 1: ...bsite at www whirlpool ca HOTTE DE CUISINIÈRE À MONTAGE MURAL DE 30 ET 36 76 2 ET 91 4 CM Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou service composer le 1 800 807 6777 ou visiter notre site Web à www whirlpool ca Table of Contents Table des matières 2 LIB0098810D W11134239B IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL U...

Page 2: ...ntains one or more chemicals known to the State of California to cause birth defects or other reproductive harm RANGE HOOD SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Venting Requirements 5 Electrical Requirements 6 INSTALLATION INSTRUCTIONS 7 Prepare Location 7 Install Range Hood 8 Connect Vent System 8 Make Electrical Connection 9 Install Vent Covers 9 Complete...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Page 4: ...es Have a qualified technician install the range hood It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimens...

Page 5: ...r enclosed area Do not use 4 10 2 cm laundry type wall cap Use metal vent only Rigid metal vent is recommended Plastic or metal foil vent is not recommended The length of vent system and number of elbows should be kept to a minimum to provide efficient performance For the Most Efficient and Quiet Operation Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent b...

Page 6: ...s Ensure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate A...

Page 7: ...ng used 6 For wood install 2 5 x 45 mm mounting screws Leave a 1 4 6 4 mm gap between the wall and the back of the screw head to slide range hood into place For wall anchors install the 10 x 60 mm wall anchors and install the 5 4 x 75 mm screws into the wall anchors Tighten until the wall anchors are secure Back the screws out 1 4 6 4 mm Vent Cover Bracket Installation 7 Attach vent cover bracket ...

Page 8: ...Use the optional wall anchors if needed ConnectVent System 1 Install transition on top of hood if removed for shipping with 2 3 5 x 9 5 mm sheet metal screws For vented installations only 1 Fit vent system over the exhaust outlet 2 Seal connection with clamps 3 Check that back draft dampers work properly For non vented recirculating installation only 1 Assemble the air deflector with the duct cove...

Page 9: ...nformation on ordering NOTE Use only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood InstallVent Covers 1 When using both upper and lower vent covers push lower cover down onto hood and lift upper cover to ceiling and install with two 4 2 x 8 mm screws NOTE For vented installations the upper vent cover may be reversed to hide...

Page 10: ...urn the blower on and control the blower speed and sound level for quiet operation The speed can be changed anytime during fan operation by pressing the desired Blower Speed button The Blower Off button turns the blower off Operating the Ambient Lighting The switch controls the ambient lighting 1 Press to the left to turn Auto On 2 Press to the right to turn Ambient Lighting On 3 Press to the cent...

Page 11: ...washer or hot detergent solution 4 Reinstall the filter by making sure the spring release handles are toward the front Insert aluminum filter into upper track 5 Push in spring release handle 6 Push up on metal filter and release handle to latch into place Non Vented recirculating Installation Filters The charcoal filter is not washable It should last up to 6 months with normal use Replace with Cha...

Page 12: ... Temp Light Sensor Turns on at 10 LUX Turns off at 50 LUX Output Input P1 P2 P4 P3 Driver Output 700mA 2 15 VDC Input 120 VAC Strip LED Ambient Light Switch Function On Off Auto Position Position 3 Position 2 Position 1 3 2 1 3 3 2 2 M N Input 120 VAC Output 700mA 2 15 VDC Driver L N G BK WH YL GN RD WH BU BK BR YL 2 1 L 3 M La POS 1 POS 2 POS 3 1 2 3 BU WH RD BR WH YL BK RD WH YL GN YL GN WH RD B...

Page 13: ...rlpool Corporation with any questions or concerns at Whirlpool Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Canada Call the Whirlpool Canada Customer eXperience Centre toll free 1 800 807 6777 or visit our website at www whirlpool ca Our Consultants Provide Assistance With Scheduling of ...

Page 14: ... use of non genuine Whirlpool parts or accessories 6 Conversion of your product from natural gas or L P gas or reversal of appliance doors 7 Damage from accident misuse abuse fire floods acts of God or use with products not approved by Whirlpool 8 Repairs to parts or systems to correct product damage or defects caused by unauthorized service alteration or modification of the appliance 9 Cosmetic d...

Page 15: ...ièces ou accessoires Whirlpool non authentiques 6 Conversion de votre produit du gaz naturel ou du gaz de pétrole liquéfié ou inversion des portes de l appareil 7 Dommages causés par accident mésusage abus incendie inondations catastrophe naturelle ou l utilisation de produits non approuvés par Whirlpool 8 Réparations aux pièces ou systèmes dans le but de rectifier un dommage ou des défauts résult...

Reviews: