Displaying System Information
Operation
32
User Menu
User Menu
Parameter
Meaning
Typical Range
Heat Manage
The heat management function – see section entitled
Turning on heat management.
ON or OFF (default).
Temp Setpoint
The temperature in °C that the coolant is to be
maintained at during operation of the WhisperGen –
see section entitled Setting the coolant temperature.
45 to 70°C (default is 60°C).
Auto-charge
The Auto-charge function – see section entitled Auto-
charging the battery bank.
ON or OFF (default).
Ext. Control
The external or remote control function – see section
entitled Remote controlling.
ON or OFF (default).
Ext Control Mode
The mode of operation for the external or remote
control switch – see section entitled Remote
controlling.
1, 2 (default), or 3.
Max Run Hours
The number of hours of operation after which the
WhisperGen is to stop. This parameter setting is a
"timer" by which the WhisperGen operates – see
section entitled Setting the maximum run time.
1 to 24 hours, or 25 hours
for continuous operation
(default).
Fault/Warning Menu
Fault/Warning Menu
Parameter
Meaning
Typical Range
Warning Code Edit to clear
The current warning code and the warning clearing
function – see section 2.8.
100 to 199.
Current Warning
The code of the prevailing warning, if there is one.
100 to 199.
Last Warning
The code of the last warning.
100 to 199.
2nd Last Warning
The code of the warning prior to the last.
100 to 199.
Current Fault
The code of the prevailing fault, if there is one.
2 to 99.
Last Fault
The code of the last fault.
2 to 99.
2nd Last Fault
The code of the fault prior to the last.
2 to 99.
Start Code
The code indicating how the WhisperGen
TM
last
started. "1" = "manual start"; "2" = "auto-charge start";
"3" = "external control start".
1, 2, or 3.
Stop Code
The code indicating how the WhisperGen
TM
last
stopped. "9" = "fault"; "1" = "manual stop"; "2" =
"battery charge complete"; "3" = "external control
stop"; "4" = "max run hours exceeded"; "5" = "parallel
charger turned on".
9YY, X1, X2, X3, X4, or X5
where YY is the code of the
prevailing fault and X is the
start code.