INSTALLING THE EVAPORATOR UNIT
NOTE:
You are
REQUIRED
to use only the mounting locations provided
.
These locations
ensure that the installer will not drill into any copper or electrical wiring within the system.
LINE SET
MOUNTING BRACKET
DRAIN LINE
POWER WIRE
KNOCKOUT
BOTTLE PROBE &
DISPLAY CABLE
KNOCKOUT
6.
Using copper tubing per line set sizing chart, route the liquid and suction lines to the tubing coming from the unit
7.
Connect
the
line set to system using
the line set connection instructions
8.
Insulate the suction line using Armaflex or similar insulation.
9.
Route the drain line out of the evaporator unit with the line set
.
10.
Connect
hard line
drain tubing to provided flex tubing