www.whisperkool.com | Page 21
Ceiling Mount
Condensation Drain Line
The condensation drain line tube is used to remove excess condensation from the unit to a proper discharge location. It
is important that the drain line tube is properly connected.
Failure to use the condensation drain line tube will void the warranty on the unit.
Drain Line
The Ceiling Mount evaporator unit features a drain line pump system that removes excessive condensate build up in
the drain pan. During operation, the drain pan collects water that drips from the coil. The drain line pump system will
prevent overflow and leaking by allowing for discharge of the additional condensate.
Connecting the Drain Line
Route the drain line to an appropriate discharge location and connect the opposite end to
the tubing that was routed out with the line set using the provided barbed coupling side of the
condensate pump. Do not route the drain line more than 15 vertical ft.
Drain Recommendations
It is recommended that the line connected to the 1/4" clear plastic line is a
rigid drain line
.
The line should be sloped towards the discharge location to help with the removal of water.
A T fitting with a cap is recommended towards the connection point of the two lines to
help with
cleaning out the line
when needed.
To prevent mold from growing, allow the
drain line to hang above the water line.
1/4" Clear Plastic Tubing
Rigid drain line
Proper Discharge
Location
WRONG:
Drain line is under water.
DRAIN LINE
Page 20
08/04/21