LINE SET, DRAIN TUBE, and ELECTRICAL CONNECTIONS
•
Line set, drain tube and electrical connections have been relocated to be accessible from the bottom (cellar side / grille
side) located on return side of unit.
•
Can be accessed by removing the grille.
•
Flare fittings have been added to the line set.
•
Liquid line – ¼” flare fitting.
•
Suction line – ½” flare fitting.
•
Connect Flare nuts from line set to system using Crescent wrenches or torque wrench.
•
Pressure test is mandatory after connecting line set to the unit.
• Verify there are no leaks before beginning vacuum and charging process.
ADDITIONAL ACCESS HOLES
•
Top access holes.
• 1 large hole for line set.
• 1 small hole for electrical.
• Note: do not run electrical wiring through same hole as line set.
•
Side access holes.
• 1 large hole for line set.
• 1 small hole for electrical.
• Note: do not run electrical wiring through same hole as line set.
•
Use the provided plug to cover the small hole not in use.
•
Use the provided sticker (4” x 4”) to cover the large hole not in use.
•
Use the provided strain relief clamp to route electrical wiring into unit.
•
Seal around line set hole with cork tape, or other insulation to ensure proper seal.
•
Note: side access holes will be applicable only if utilizing the flush mounting option.
Page 42