background image

3

TECHNICAL DATA

GENERAL

Front loading tumble dryer with gas heating. Reverse action
drum tumble. Time control. 2-temperature exhaust
thermostat control. Induced air flow enters dryer through
front grille, some passes through the gas burner into the
rear ducting and some into the cooling passages, this
mixed air enters the drum through the rear perforations,
passes through the clothes, lint filter, and the fan and is
discharged through the vent at the rear.

CONNECTIONS

Gas pressure: Rp 

1

/

2

(

1

/

2

” B.S.P. parallel internal thread).

Nominally 20mb

Electric:

230V. 50 Hz, earthed supply, 13A fuse.
(wall socket must have efficient earth
connection and correct polarity)

DIMENSIONS

Height 85 cms. (33

1/

2

”)

Width  59.6 cms. (23

1/

4

”)

Depth 57 cms. (22

1/

2

”)

Depth when rear vent hose assembled 60cms. (23

5/

8

”)

WEIGHT

With packing

37 kg

Without packing 36 kg

SUPPORT

Machine rests on 2 rear positioned rollers and 2 non
adjustable feet.

AIR-FLOW

Approximately 120 cubic metres per hour with capacity
clothes load.

IDENTITY

Manufacture date, and serial number are displayed on a
plate revealed when machine door is open.
The first 4 numerals identify year and week of manufacture.
The  last  6  numerals  identify the  machine. ALL
INFORMATION FROM THIS PLATE SHOULD BE
QUOTED IN ANY SERVICE COMMUNICATION.

COMPONENTS

DRIVE MOTOR

Permanent split capacitor (8µF) 4 pole—Approx.

1

/

8

HP

Overload protection approx. 130°C

BURNER

Pressed steel with slotted flame perforations.
Heat input: 3.0kW (10235 Btu/hr). Injector 1.32 mm dia.

CONTROL

Type: Pactrol full sequence flame control, P16A GTD(CE)
414601. Ignition electrode gap to burner 3 to 4mm Flame
failure electrode (4213 078 52641). Height from heater
base to centre of electrode 27.0±0.5mm.

INLET THERMOSTAT

(Brown wires identification)
Bi-metal contacts normally closed.
Contacts open if airflow restricted.
Contacts open 130˚C ± 3˚C
Contacts reset 100˚C ± 5˚C

INLET TEMPERATURE  LIMITER

(White wires identification)
Bi-metal contacts normally closed.
Contacts open if INLET THERMOSTAT fails.
Contacts open 143˚C ± 4˚C
Contacts reset 95˚C ± 10˚C

EXHAUST THERMOSTATS

Bi-metal contacts normally closed.
Normal Fabrics:

Contacts open 60˚C ± 3˚C

60˚C (green spot 

Contacts reset 49˚C ± 4˚C

identification)
Delicate Fabrics:

Contacts open 50˚C ± 3˚C

50˚C (red spot 

Contacts reset 39˚C ± 4˚C

identification)

DRUM

Volume

105 litres

Speed

approx. 50/59 r.p.m.

Capacity

5 kg dry cotton

Rotation

clockwise 6 mins., anticlockwise 10 secs

TRANSMISSION

Poly-vee belt driven by vee-grooved motor pulley to outer
circumference of drum.

TIMER

Electric 120 minutes combined forward and reverse 6
min cycle with 10 seconds reverse.

HEATER SWITCH

Single pole, ON/OFF

R.F.I. FILTER

0.1µF + 2x 2x5mH + 2M2

ACCESSORIES

VENT HOSE ASSEMBLY

0312 001 01001

WALL/WINDOW VENT KIT

0312 005 01001

STACKING KIT

0312 003 01001

RESTRAINING KIT

0312 006 01001

Summary of Contents for 43A

Page 1: ...ety Installation and Use Regulations 1998 Guidance may be obtained from the relevant parts of B S 6172 B S 5440 parts 1 and 2 B S 7624 2004 B S 6891 current editions I E E Wiring Regulations and relevant Building Regulations Failure to install the appliance correctly could invalidate the warranty liability claims and could lead to prosecution FOR USE IN GREAT BRITAIN AND EIRE WITH NATURAL GAS ONLY...

Page 2: ...OCAL REGULATIONS IN FORCE AND ONLY IN A WELL VENTILATED SPACE READ THE INSTRUCTIONS BEFORE USING OR INSTALLING THIS APPLIANCE THIS APPLIANCE CONFORMS TO THE FOLLOWING EEC DIRECTIVES LOW VOLTAGE DIRECTIVE LVD 73 23 EEC EN60 335 1 EN60 335 2 11 GAS APPLIANCE DIRECTIVE GAS 90 396 EEC BS 5258 PART 17 1992 EN 1458 1 2000 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC EN55014 EN 61000 3 2 EN 61000 3...

Page 3: ...t split capacitor 8µF 4 pole Approx 1 8 HP Overload protection approx 130 C BURNER Pressed steel with slotted flame perforations Heat input 3 0kW 10235 Btu hr Injector 1 32 mm dia CONTROL Type Pactrol full sequence flame control P16A GTD CE 414601 Ignition electrode gap to burner 3 to 4mm Flame failure electrode 4213 078 52641 Height from heater base to centre of electrode 27 0 0 5mm INLET THERMOS...

Page 4: ...ion Note Do not obstruct or add a mesh to the vent hose outlet during use and ensure that it cannot be blocked or bent sharply which obstruct the air flow It is recommended that the interior of the hose be periodically inspected and cleaned if necessary PERMANENT VENTING Accessory wall window vent kit CL005 is available See illustration for necessary hole through wall Dim A 200mm and Dim B 100mm f...

Page 5: ...ed tumble dryers 9 STACKING Instructions for stacking if required are supplied with the stacking kit PROGRAMME Clockwise rotation of the control knob closes switch contacts within the timer to a energise the drive motor and b energise the full sequence flame controller The timer switch controlling the drive motor and the timer motor remains closed until the timer motor mechanism returns the contro...

Page 6: ...way Housing 31 to release the wiring from the Heater Assy to the Cabinet Lay the dryer flat on its front supported to take the weight from the door and controls Withdraw the 6 screws securing the Cover Piate 19 to the Back Panel 24 and remove it Pull out the Exhaust Tube 30 Withdraw the 4 screws securing the Hot Air Elbow Assy 20 to the Back Panel 24 and remove it Disconnect the External Feed Pipe...

Page 7: ... there is a fault in the valves burner or other parts of the gas line then the Heater Assy 32 must be replaced INLET THERMOSTAT THERMAL OVERLOAD CUT OUT TOC REMOVAL Lay the dryer flat on its front supported to take the weight from the door and controls Withdraw the 6 screws securing the Cover Plate 19 to the Back Panel 24 and remove it Pull out the Exhaust Tube 30 Disconnect the Faston connectors ...

Page 8: ... With door closed timer ON 30 min is voltage between terminal B12 on timer orange wire and TB N 230V Substitute capacitor Does motor run Refit capacitor change motor With motor running does gas attempt to light Does gas light Does gas stay on Machine operating Instruct users as necessary Yes Yes Refer to chart 2 No No No No No No No No No Refer to chart 3 No Refer to chart 4 No No No No No No No N...

Page 9: ...k with high heat selected Disconnect both red wires at timer B2 Reconnect only red wire from heat selector to timer B2 Caution the other red wire is live Is voltage between heat selector switch and TB N 230V With red wire still disconnected is voltage between output of heat selector switch and TB N 230V at high heat setting and zero volts at low setting Is voltage between brown wire in control box...

Page 10: ...10 Chart 3 Motor runs Full Sequence Control produces ignition sparks but gas does not ignite ...

Page 11: ...ay cause back pressure Is flame failure electrode correctly positioned and undamaged Is wire to terminal 9 undamaged and connections tight Is rear drum seal complete Is rear elbow and plinth attached correctly Exchange Full Sequence Control and or Thermostats as necessary until gas stays ON Machine operating Instruct user as necessary Yes Yes Yes Start Check gas pressure with all other appliances ...

Page 12: ...12 WHITE KNIGHT BG 43A_ CROSSLEE P L C FUNCTIONAL FLOW WIRING DIAGRAM BG 43A_ ...

Page 13: ...13 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 1 ...

Page 14: ...14 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 2 REAR ASSEMBLY VIEWED FROM FRONT ...

Page 15: ...15 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 3 INTERNALS VIEWED FROM REAR ...

Page 16: ...WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 4 INTERNALS VIEWED FROM REAR 16 ...

Page 17: ...17 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 5 HEATER ASSEMBLY ...

Page 18: ... Electrode 4213 092 19801 5 34 Flame Tube Assembly 4213 089 07842 5 37 Test Nipple Plug 4213 073 49492 5 38 Inlet Temperature Limiter 143 Deg C 4213 092 24151 2 39 Ignition Electrode 4213 092 08491 5 41 M4 x 10 Pan Screw 2522 178 08082 5 45 Solenoid Coil SCEM 4213 092 08501 5 101 Motor and Capacitor Assembly 4213 092 25611 3 101a Motor Ceset Olmo see 101 3 112 Capacitor µf 4213 092 08091 3 125 Dri...

Page 19: ...n 4213 077 89001 1 393 Flex Support Clip 4213 077 40982 1 2 394 Foot 4213 077 39832 1 396 Flb Ear Scr St Zn 8 x 3 8 2513 200 06166 1 2 3 398 Screw M4 x 25 2522 178 25087 2 3 403 Roller Assembly 4213 092 35651 2 405 Earth Tab 4213 070 14681 2 408 Cable Clamp 4213 077 47303 2 409 Washer M5 Form A 2522 600 65029 2 409 M5 Form A Washer 2522 600 65029 3 410 Screw 6AB x 13 2522 163 52115 2 411 M4 Hex Nu...

Page 20: ... 448 Fan Spring Clip 4213 075 71162 4 451 Fln Tap Scr St Zn 8 x 1 2 2513 152 02001 1 454 Filter 4213 092 17821 4 455 Screw 6 x 12 2522 164 26009 4 456 Banjo Seal 4213 077 07991 4 458 Banjo Insert No 2 4213 077 53502 4 459 Banjo Insert No 1 4213 077 53492 4 482 M4 Toothed Lockwasher 2522 616 15007 5 537 W Button access cover 4213 078 26311 4 554 Timer Shaft Support 4213 077 60081 1 555 Rear Panels ...

Reviews: