6. OPERATIONAL CHECK

6.1  Remove the pressure test point screw from the gas

tee connection at the back of the dryer and connect
a gas pressure gauge.

6.2 Check that the dryer timer is in the 'off' position, and

that the heat switch is set to 'high'.

Remove anything from inside the drum, check that
the lint filter is fitted, shut the dryer door.

6.3  Turn on the gas, push the electric plug into the socket

and switch on the electricity supply.

6.4  Turn the timer clockwise past the dotted line marking

the cool-down period to a setting of at least 30 mins.
Check for ignition. If the gas fails to remain lit then
repeatedly turn the timer on and off (or open and
close the door) for periods of at least 30 seconds
until the air is removed from the system and burning
is continuous. Note that gas is not lit when the drum
is turning anti-clockwise.

6.5 With the gas burning ensure that the pressure is as

detailed in the Technical Data. Turn off and replace
the pressure test point screw. Check for soundness.

6.6 Switch on again and re-start so that the gas is

burning.Disconnect the flexible gas hose and check
that the solenoids can be heard to close. After 30
seconds turn on the gas and check that there is no
re-ignition. Switch the machine off and on again and
check for reignition.

6.7 Check that the operation of the machine does not

cause spillage of products of combustion from any
open flued gas appliance in the same room, or from
appliances in adjoining rooms, e.g. a gas fire or
central heating boiler.

6.8 In the event of an electrical fault after installation of

the appliance, preliminary electrical system checks
must be carried out (i.e. earth continuity, polarity and
resistance to earth).

6.9

IMPORTANT INFORMATION RE-FUNCTIONING
OF THE FULL SEQUENCE FLAME CONTROL
BOX.

THE FULL SEQUENCE FLAME CONTROL BOX
ON THIS APPLIANCE REQUIRES A 6 SECOND
RE-SET PERIOD FOLLOWING EACH
INTERRUPTION OF INPUT VOLTAGE.

6 SECONDS DELAY IS REQUIRED BETWEEN
EACH ATTEMPT TO RESTART THE APPLIANCE
FOLLOWING SWITCHING IT OFF, OR AFTER
OPENING THE DOOR.

7

AIRFLOW

It is most important that airflow to the plinth is not
restricted.

8

MAINTENANCE

It is recommended that the appliance is serviced
annually by a person competent to service gas fired
tumble dryers.

9

STACKING

Instructions for stacking, if required, are supplied
with the stacking kit.

PROGRAMME

Clockwise rotation of the control knob closes switch
contacts within the timer to: a) energise the drive motor,
and b) energise the full sequence flame controller.

The timer switch controlling the drive motor and the timer
motor, remains closed until the timer motor mechanism
returns the control knob to the '0' position. The timer
switch controlling the full sequence flame controller
opens 12 minutes earlier to provide a cool-down period.

The full sequence flame controller opens the tandem
solenoid gas valves after a delay time of about 8 seconds
and operates the pulsing spark ignition. If the flame is not
detected by the flame failure electrode within 10 seconds
then the valves are closed. The system must then be re-
set by switching the machine off and re-starting.

The heat selector switch provides options for either 60°C,
or 50°C, exhaust thermostat control. This results in the
burner cycling on and off giving Ionger than anticipated
drying times. Drying times vary depending on the weight
and size of the articles, type of fabric, dampness etc.
These thermostats turn off the heating towards the end of
the chosen cycle and so avoid waste of energy. The lower
temperature thermostat prevents delicate fabrics from
getting too hot with possible risk of damage.

An inlet thermostat is fitted in the ducting at the back of
the dryer. It may also operate under certain other
conditions of restriction of the air-flow, for example, an
overloaded drum or blocked lint filter. This thermostat
switches off the flame controller. This will result in the
burner cycling on and off giving longer than anticipated
drying times. Drying times vary depending on the weight
and size of the articles, type of fabric, dampness etc.

Should the thermostat fail there is an inlet cut-out
connected in circuit with the gas valves. After operation,
the cut-out must be re-set to restore heating but a service
call may be required to correct the initial fault.

The conditions of failure of the air flow, blow-back, or of
gas interruption are detected by the flame failure
electrode and the system is shut-down.

Both drum rotation and heater control are switched off
when the door is opened and switched on when the door
is reclosed.

For programme times see chart on dryer control panel.

Note:

Do not allow fluff to accumulate around the dryer.

Summary of Contents for 43A

Page 1: ...ety Installation and Use Regulations 1998 Guidance may be obtained from the relevant parts of B S 6172 B S 5440 parts 1 and 2 B S 7624 2004 B S 6891 current editions I E E Wiring Regulations and relevant Building Regulations Failure to install the appliance correctly could invalidate the warranty liability claims and could lead to prosecution FOR USE IN GREAT BRITAIN AND EIRE WITH NATURAL GAS ONLY...

Page 2: ...OCAL REGULATIONS IN FORCE AND ONLY IN A WELL VENTILATED SPACE READ THE INSTRUCTIONS BEFORE USING OR INSTALLING THIS APPLIANCE THIS APPLIANCE CONFORMS TO THE FOLLOWING EEC DIRECTIVES LOW VOLTAGE DIRECTIVE LVD 73 23 EEC EN60 335 1 EN60 335 2 11 GAS APPLIANCE DIRECTIVE GAS 90 396 EEC BS 5258 PART 17 1992 EN 1458 1 2000 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 89 336 EEC EN55014 EN 61000 3 2 EN 61000 3...

Page 3: ...t split capacitor 8µF 4 pole Approx 1 8 HP Overload protection approx 130 C BURNER Pressed steel with slotted flame perforations Heat input 3 0kW 10235 Btu hr Injector 1 32 mm dia CONTROL Type Pactrol full sequence flame control P16A GTD CE 414601 Ignition electrode gap to burner 3 to 4mm Flame failure electrode 4213 078 52641 Height from heater base to centre of electrode 27 0 0 5mm INLET THERMOS...

Page 4: ...ion Note Do not obstruct or add a mesh to the vent hose outlet during use and ensure that it cannot be blocked or bent sharply which obstruct the air flow It is recommended that the interior of the hose be periodically inspected and cleaned if necessary PERMANENT VENTING Accessory wall window vent kit CL005 is available See illustration for necessary hole through wall Dim A 200mm and Dim B 100mm f...

Page 5: ...ed tumble dryers 9 STACKING Instructions for stacking if required are supplied with the stacking kit PROGRAMME Clockwise rotation of the control knob closes switch contacts within the timer to a energise the drive motor and b energise the full sequence flame controller The timer switch controlling the drive motor and the timer motor remains closed until the timer motor mechanism returns the contro...

Page 6: ...way Housing 31 to release the wiring from the Heater Assy to the Cabinet Lay the dryer flat on its front supported to take the weight from the door and controls Withdraw the 6 screws securing the Cover Piate 19 to the Back Panel 24 and remove it Pull out the Exhaust Tube 30 Withdraw the 4 screws securing the Hot Air Elbow Assy 20 to the Back Panel 24 and remove it Disconnect the External Feed Pipe...

Page 7: ... there is a fault in the valves burner or other parts of the gas line then the Heater Assy 32 must be replaced INLET THERMOSTAT THERMAL OVERLOAD CUT OUT TOC REMOVAL Lay the dryer flat on its front supported to take the weight from the door and controls Withdraw the 6 screws securing the Cover Plate 19 to the Back Panel 24 and remove it Pull out the Exhaust Tube 30 Disconnect the Faston connectors ...

Page 8: ... With door closed timer ON 30 min is voltage between terminal B12 on timer orange wire and TB N 230V Substitute capacitor Does motor run Refit capacitor change motor With motor running does gas attempt to light Does gas light Does gas stay on Machine operating Instruct users as necessary Yes Yes Refer to chart 2 No No No No No No No No No Refer to chart 3 No Refer to chart 4 No No No No No No No N...

Page 9: ...k with high heat selected Disconnect both red wires at timer B2 Reconnect only red wire from heat selector to timer B2 Caution the other red wire is live Is voltage between heat selector switch and TB N 230V With red wire still disconnected is voltage between output of heat selector switch and TB N 230V at high heat setting and zero volts at low setting Is voltage between brown wire in control box...

Page 10: ...10 Chart 3 Motor runs Full Sequence Control produces ignition sparks but gas does not ignite ...

Page 11: ...ay cause back pressure Is flame failure electrode correctly positioned and undamaged Is wire to terminal 9 undamaged and connections tight Is rear drum seal complete Is rear elbow and plinth attached correctly Exchange Full Sequence Control and or Thermostats as necessary until gas stays ON Machine operating Instruct user as necessary Yes Yes Yes Start Check gas pressure with all other appliances ...

Page 12: ...12 WHITE KNIGHT BG 43A_ CROSSLEE P L C FUNCTIONAL FLOW WIRING DIAGRAM BG 43A_ ...

Page 13: ...13 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 1 ...

Page 14: ...14 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 2 REAR ASSEMBLY VIEWED FROM FRONT ...

Page 15: ...15 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 3 INTERNALS VIEWED FROM REAR ...

Page 16: ...WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 4 INTERNALS VIEWED FROM REAR 16 ...

Page 17: ...17 WHITE KNIGHT BG 43A_ CROSSLEE P L C EXPLODED VIEW 5 HEATER ASSEMBLY ...

Page 18: ... Electrode 4213 092 19801 5 34 Flame Tube Assembly 4213 089 07842 5 37 Test Nipple Plug 4213 073 49492 5 38 Inlet Temperature Limiter 143 Deg C 4213 092 24151 2 39 Ignition Electrode 4213 092 08491 5 41 M4 x 10 Pan Screw 2522 178 08082 5 45 Solenoid Coil SCEM 4213 092 08501 5 101 Motor and Capacitor Assembly 4213 092 25611 3 101a Motor Ceset Olmo see 101 3 112 Capacitor µf 4213 092 08091 3 125 Dri...

Page 19: ...n 4213 077 89001 1 393 Flex Support Clip 4213 077 40982 1 2 394 Foot 4213 077 39832 1 396 Flb Ear Scr St Zn 8 x 3 8 2513 200 06166 1 2 3 398 Screw M4 x 25 2522 178 25087 2 3 403 Roller Assembly 4213 092 35651 2 405 Earth Tab 4213 070 14681 2 408 Cable Clamp 4213 077 47303 2 409 Washer M5 Form A 2522 600 65029 2 409 M5 Form A Washer 2522 600 65029 3 410 Screw 6AB x 13 2522 163 52115 2 411 M4 Hex Nu...

Page 20: ... 448 Fan Spring Clip 4213 075 71162 4 451 Fln Tap Scr St Zn 8 x 1 2 2513 152 02001 1 454 Filter 4213 092 17821 4 455 Screw 6 x 12 2522 164 26009 4 456 Banjo Seal 4213 077 07991 4 458 Banjo Insert No 2 4213 077 53502 4 459 Banjo Insert No 1 4213 077 53492 4 482 M4 Toothed Lockwasher 2522 616 15007 5 537 W Button access cover 4213 078 26311 4 554 Timer Shaft Support 4213 077 60081 1 555 Rear Panels ...

Reviews: