Page 11
19400-3-0406
Note:
Dimension "C" is the minimum with the fireplace face extending 1/2" in
front of the framing to allow for finishing materials.
Figure 11
Attention:
Add 3-3/4" to “A” dimensions when using a flush
mantel base.
Attention:
If a base or mantel is not used and the appliance is
installed directly on carpeting, tile or other combustible material
other than wood flooring, it shall be installed on a metal or wood
panel extending the full width and depth of the appliance. The
vertical dimension in Figure 11 must be adjusted when a metal or
wood panel is placed beneath the appliance.
Finishing (Figure 12)
Finish the walls with the material of your choice. Only non-
combustible materials may be used to cover the black fireplace
front.
Warning: When finishing the fireplace never obstruct
or modify the air inlet/outlet louvers in any manner.
Provide adequate clearances around air openings into the
combustion chamber.
Caution:
If the joints between the finished wall and the fireplace
surround (top and sides) are sealed, a 300°F minimum sealant
material must be used. These joints are not required to be sealed.
Only non-combustible material (using 300°F minimum adhesive
if needed), can be applied as facing to the fireplace surround.
Combustible Surround Installation
Figure 12
Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated exterior
wall, it is recommended that the outer walls be insulated
to conform to applicable insulation codes.
FINISHED WALL
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
MATERIAL (SEALANT IS OPTIONAL)
° C
SEALANT
COMBUSTIBLE SURROUND
MANTELSHELF
2 X 4
HEADER
STAND OFF
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL MAY OVERLAP BLACK PAINTED
FACE (INSTALLATION IS OPTIONAL)
INSTALLATION (CONT)
Minimum Framing Dimensions
BVD34
BVD36
BVP42
"A"
35 3/4"
(908mm)
37 3/4"
(959mm)
37 3/4"
(959mm)
"B"
37 3/8"
(949mm)
39 3/8"
(1,000mm)
43 3/8"
(1,102mm)
"C"
14 3/8"
(378mm)
17 7/8"
(454mm)
17 7/8"
(454mm)