Some people cannot smell well. Some people cannot smell the 

odor of the chemical put into the gas. You must find out if you 

can smell the odorant in propane.

 Smoking can decrease your 

ability to smell. Being around an odor for a time can affect your 

sensitivity or ability to detect that odor. Sometimes other odors 

in the area mask the gas odor. People may not smell the gas odor 

or their minds are on something else. Thinking about smelling a 

gas odor can make it easier to smell.

The odorant in LP-Gas is colorless, and it can fade under some 

circumstances.

 For example, if there is an underground leak, the 

movement of the gas through soil can filter the odorant. Odorants 

in LP-Gas also are subject to oxidation. This fading can occur if 

there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, 

masonry and other materials and fabrics in a room. That will take 

some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could 

vary at different levels. Since it is heavier than air, there may be 

more odor at lower levels. Always be sensitive to the slightest gas 

odor. If you detect any odor, treat it as a serious leak. Immediately 

go into action as instructed earlier.

Propane (LP-Gas) is a flammable gas which can cause fires 

and explosions. In its natural state, propane is odorless and 

colorless. You may not know all the following safety precau-

tions which can protect both you and your family from an 

accident. Read them carefully now, then review them point 

by  point  with  the  members  of  your  household.  Someday 

when there may not be a minute to lose, everyone’s safety 

will depend on knowing exactly what to do. If, after read-

ing the following information, you feel you still need more 

information, please contact your gas supplier.

• 

Learn to recognize the odor of LP-Gas.

 Your local LP-Gas 

Dealer can give you a “Scratch and Sniff” pamphlet. Use it to 

find out what the propane odor smells like. If you suspect that 

your LP-Gas has a weak or abnormal odor, call your LP-Gas 

Dealer.

•  If you are not qualified, do not light pilot lights, perform service, 

or make adjustments to appliances on the LP-Gas system. If 

you are qualified, consciously think about the odor of LP-Gas 

prior to and while lighting pilot lights or performing service 

or making adjustments.

•  Sometimes a basement or a closed-up house has a musty smell 

that can cover up the LP-Gas odor. Do not try to light pilot 

lights, perform service, or make adjustments in an area where 

the conditions are such that you may not detect the odor if 

there has been a leak of LP-Gas.

•  Odor fade, due to oxidation by rust or adsorption on walls of 

new cylinders and tanks, is possible. Therefore, people should 

be particularly alert and careful when new tanks or cylinders 

are placed in service. Odor fade can occur in new tanks, or 

reinstalled old tanks, if they are filled and allowed to set too 

long before refilling. Cylinders and tanks which have been 

out of service for a time may develop internal rust which will 

cause odor fade. If such conditions are suspected to exist, a 

periodic sniff test of the gas is advisable. 

If you have any 

question about the gas odor, call your LP-Gas dealer. A 

periodic sniff test of the LP-Gas is a good safety measure 

under any condition.

•  If, at any time, you do not smell the LP-Gas odorant and you 

think you should, assume you have a leak. Then take the same 

immediate action recommended above for the occasion when 

you do detect the odorized LP-Gas.

•  If you experience a complete “gas out,” (the container is under 

no vapor pressure), turn the tank valve off immediately. If the 

container valve is left on, the container may draw in some air 

through openings such as pilot light orifices. If this occurs, 

some  new  internal  rusting  could  occur.  If  the  valve  is  left 

open, then treat the container as a new tank. Always be sure 

your container is under vapor pressure by turning it off at the 

container before it goes completely empty or having it refilled 

before it is completely empty.

•  Do not operate electric switches, light matches, use your phone. 

Do not do anything that could ignite the gas.

•   Get everyone out of the building, vehicle, trailer, or area. Do 

that IMMEDIATELY.

•   Close all gas tank or cylinder supply valves.

•   LP-Gas is heavier than air and may settle in low areas such as 

basements. When you have reason to suspect a gas leak, keep 

out of basements and other low areas. Stay out until firefighters 

declare them to be safe.

•   Use your neighbor’s phone and call a trained LP-Gas service 

person  and  the  fire  department.  Even  though  you  may  not 

continue to smell gas, do not turn on the gas again. Do not 

re-enter the building, vehicle, trailer, or area.

•  

Finally

, let the service man and firefighters check for escaped 

gas. Have them air out the area before you return. Properly 

trained  LP-Gas  service  people  should  repair  the  leak,  then 

check and relight the gas appliance for you.

SOME POINTS TO REMEMBER

NO ODOR DETECTED - ODOR FADE

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. 

That’s your signal to go into immediate action!

SAFETY INFORMATION FOR USERS OF LP GAS

Summary of Contents for DV25IN33L

Page 1: ...iance is not convertible for use with other gases unless a certified kit is used GAS FIRED Installer Leave this manual with the appli ance Consumer Retain this manual for future refer ence Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch d...

Page 2: ... 10 12 Vertical Termination 13 Alternate ON OFF Switch Installation 14 Surround Panel Installation 15 Blower Accessory Information 16 Log Placement 17 Operating Instructions 18 Standing Pilot Lighting Instructions 19 Standing Pilot Wiring 20 Standing Pilot Troubleshooting 21 Insert Maintenance and Service 22 Decorative Accessories 23 Insert Parts View 24 Insert Parts List 25 How to Order Repair Pa...

Page 3: ...t clean Vent cap is hot while fireplace is in operation Installation and repair should be done by a QUALIFIED SERVICE PERSON The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding materials etc It is imperative that control compartments burners and circulating air passageway...

Page 4: ...s perform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of new cylinders and tanks is possible Therefore people should be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled ...

Page 5: ...aving jurisdiction State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code or CSA B149 1 in Canada Available from the American National Standards Institute I...

Page 6: ...alling to an existing round fireplace chimney pipe DVVK3FV Vertical Vent Kit 25 Two pieces of 25 FlexVent Rectangle Cap Flashing connectors and clamps Recommended when installing to a square or rectangular clay flue DVK35 Vent Extension Kit 35 flex vent extension section with 2 connectors and 4 clamps Note When installing vent caps special locally made flashings may be required to properly seal the ve...

Page 7: ... 28 14 1 2 11 1 8 25 1 4 12 3 4 17 18 5 16 27 6 3 4 9 20 25 3 8 40 DV33IN 22 3 8 31 16 14 1 8 28 1 4 14 1 4 18 3 4 21 5 16 30 8 1 4 10 1 2 21 1 2 28 3 8 43 DV35IN 24 3 8 34 16 16 1 8 31 1 4 14 1 4 21 3 4 23 5 16 33 8 1 4 10 1 2 23 30 3 8 46 A D C B Figure 2 Fireplace Opening Dimensional Information Sizing MINIMUM FIREPLACE OPENING DIMENSIONS MODEL NO HEIGHT A FRONT WIDTH B DEPTH C REAR WIDTH D DV2...

Page 8: ...10 1 3 4 23 11 Combustible Material No greeting cards stockings or ornamentation of any type should be placed on or attached to the fireplace The flow of heat can ignite combustibles Figure 4 8 MINIMUM CLEARANCE TO PERPENDICULAR COMBUSTIBLE SIDE WALL FROM EDGE OF DOOR FRAME Figure 3 ...

Page 9: ...res results in pressures in excess of 1 2 psig 14 w c 3 5 kPa on the fireplace gas valve it will result in a hazardous condition Checking Manifold Pressures Both Propane and Natural gas valves have a built in pressure regulator in the gas valve Natural gas models will have a manifold pressure of approximately 3 5 w c 871kPa at the valve outlet with the inlet pressure to the valve from a minimum of ...

Page 10: ...isting air circulation vents or grills NOTE Cutting of sheet metal parts of a fireplace in order to install the fireplace insert is prohibited WARNING Only the surround as supplied may be used to cover integral grills on the solid fuel burning fireplace No other components such as shrouds sheet metal plates etc may be used to seal off vents 7 To assure top performance safety and efficiency inserts mus...

Page 11: ...ry chimney may need to be removed to allow installation of the flexible vent pipe When installing into a zero clearance factory built wood burning fireplaces the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily Connecting the Vent Pipe Caution Sharp edges Always use gloves when installing Install the 3 inch flex...

Page 12: ...ENT CONNECTION RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED USE HIGH TEMP SEALANT ON VENT CONNECTIONS USE HIGH TEMP SEALANT ON VENT CONNECTIONS ROUND TERMINATION CAP DVKI KIT ROUND CO LINEAR TO CO AXIAL ADAPTOR BLOWER ACCESS COVER PLATE BLOWER POWER CORD OPTIONAL LOW VOLTA...

Page 13: ...ently dripping out at joints or seams Condensate can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs or having exterior portions of the system exposed to cold weather 4 Inspectjointstoverifythatnopipesectionsorfittingshavebeen disturbed and consequently loosened Also check mechanical supports such as wall straps or plumbers tape for rigidity Determining Mi...

Page 14: ...und panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides Lift the surround panel assembly slightly until the bottom return flange top panel is positioned over the top flange on the insert This secures the sur round panel assembly to the insert without screws Traditional Cast Iron Surrounds 1 Find the coiled low voltage wire assembly an...

Page 15: ...N FINISHING THE FIREPLACE INSERT NEVER OBSTRUCT OR MODIFY THE AIR INLET OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER NOTE INSTALL SURROUND PANELS SO THAT THE TOP PANEL RETURN FLANGE SLIDE S OVER THE TOP FLANGE ON THE INSERT 1 Ref SURROUND PANEL ASSEMBLY ENGAGE SIDE PANEL HOOKS WITH THE NOTCHES PROVIDED ON THE SIDE FLANGES Figure 14 Figure 15 ...

Page 16: ...and BTU input level setting control by adjustment of the HI LO knob located on the gas valve Blower removal instructions Servicing or removal of the blower system must be performed by a qualified service person If the blower assembly Item 45 page 24 must be replaced the following steps are recommended for removal 1 Turn off gas and disconnect the electrical supply 2 Remove the glass door assembly 3...

Page 17: ... support Note DV25IN models incorporate two small tabs in the rear log support that keep the back log positioned correctly DV33IN models have one small tab in the rear log support to ensure the back log is in the correct position The DV35IN models will have two tabs bent forward in the rear log support to ensure proper left to right positioning of the log plus one small tab near the center that ke...

Page 18: ... ON position This time period allows the millivolts electrical current to build up to a sufficient level allowing the gas control to operate properly 1 Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in control compartment behind the door assembly CAUTION Duringtheinitialpurgingandsubsequentlightings never allow the gas valve control ...

Page 19: ...witch to desired setting FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B Before lighting smell all around the appliance area for gas Be sure to smell ...

Page 20: ...Optional Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8m or less length of 18 A W G minimum wire and connect it to the fireplace valve pigtails WARNING DO NOT CONNECT THE 110 120 VAC TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED CAUTION LABEL ALL WIRES PRIOR TO DISCONNEC TION WHEN SERVICING CONTROL WIRING ERRORS CAN CAUSE IMPROPER AND...

Page 21: ...tions from the thermopile at the gas valve terminals are tight and the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading atTH TP TPterminals of the gas valve The meter shouldread350millivoltsminimum whileholdingthevalve knob depressed in the PILOT position with the pilot lit and the REMOTE OFF ON switch in the OFF position Replace the ...

Page 22: ...e that no debris is interfering with the flow of air Inspect entire vent system for proper function Cleaning Logs Use a soft brush attachment on a vacuum cleaner to gently remove dust or soot deposits from logs and burner Cleaning Glass Door Frequency After the first 3 to 4 hours of use As necessary after initial cleaning By Home owner Task Remove and clean glass after the first 3 to 4 hours of use A...

Page 23: ...hat your dealer can furnish contact Empire Comfort Systems Inc Nine Eighteen Freeburg Ave Belleville Illinois 62220 Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewter Brushed Stainless Black Gold Finish Hammered Pewter Brushed Stainless Black Black Black Standard Gold Finish Hammered Pewter Brushed Stainless Black Used to finish off bottom of insert and surround p...

Page 24: ...23015 3 0707 Page 24 INSERT PARTS VIEW ...

Page 25: ...ING ORIFICE ANGLED 23a P286 P270 P244 ORIFICE MAIN BURNER NAT 23b P214 P210 P245 ORIFICE MAIN BURNER LP 24 23311 23017 23017 BURNER ASSEMBLY 25 22959 22959 22959 VALVE BRACKET 26 22739 22738 22738 TUBING ASSEMBLY 27 22973 22973 22973 SHIELD VALVE 28a R7577 R7577 R7577 VALVE SIT GAS NAT 28b R7578 R7578 R7578 VALVE SIT GAS LP 29 22953 22953 22953 PIEZO BRACKET 30 16223 16223 16223 SPRING RETAINER AS...

Page 26: ...ine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Number Part Description Fireplace Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments c...

Page 27: ...23015 3 0707 Page 27 SERVICE NOTES ...

Page 28: ...23015 3 0707 Page 28 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ...

Reviews: