Page 12
VENT TERMINATION CLEARANCES
Canadian Installations1
US Installations2
Canadian Installations1
US Installations2
A= Clearance above grade,
veranda, porch, deck, or
balcony
12 in (30 cm)
12 in (30cm)
I= Clearance to service
regulator vent outlet
3 ft (91 cm)
6 ft
B= Clearance to window or
door that may be open
6 in (15 cm) for appli-
DQFHV%WXK
(3 kW), 12 in (30 cm)
for appliances > 10,000
%WXKN:DQG
100,000 Btuh (30 kW),
36 in (91 cm) for appli-
ances > 100,000 Btuh
(30 kW)
6 in (15 cm) for appli-
DQFHV%WXK
kW), 9 in (23 cm) for ap-
pliances > 10,000 Btuh
N:DQG
Btuh (15 kW), 12 in
(30 cm) for appliances >
50,000 Btuh (15 kW)
J= Clearance to nonme-
chanical air supply
inlet to building or the
combustion air inlet to
any other appliance
6 in (15 cm) for appli-
DQFHV%WXK
kW), 12 in (30 cm) for
appliances > 10,000
%WXKN:DQG
100,000 Btuh (30 kW),
36 in (91 cm) for appli-
ances > 100,000 Btuh
(30 kW)
6 in (15 cm) for appli-
DQFHV%WXK
(3 kW), 9 in (23 cm) for
appliances > 10,000 Btuh
N:DQG%WXK
(15 kW), 12 in (30 cm) for
appliances > 50,000 Btuh
(15 kW)
C= Clearance to perma-
nently closed window
12 in (30 cm)
12 in (30 cm)
K= Clearance to a mechani-
cal air supply inlet
6 ft (1.83 m)
3 ft (91 cm) above if
within 10 ft (3 m) hori-
zontally
D= Vertical clearance
YHQWLODWHGVRI¿WORFDWHG
above the terminal within
a horizontal distance of 2
feet (61 cm) from the cen-
ter line of the terminal
24 in (61 cm)
24 in (61 cm)
L= Clearance above paved
sidewalk or paved drive-
way located on public
property
7 ft (2.13 m) †
7 ft (2.13 m) †
E= Clearance to unventi-
ODWHGVRI¿W
12 in (30 cm)
12 in (30 cm)
M= Clearance under
veranda, porch deck, or
balcony
12 in (30 cm) ‡
12 in (30 cm) ‡
F= Clearance to outside
corner
6 in (15 cm)
6 in (15 cm)
1
In accordance with the current CSA B149.1, Natural Gas and Propane Instal-
lation Code
G= Clearance inside corner
9 in (23 cm)
9 in (23 cm)
2
In Accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas
Code
H= Clearance to each side
of center line extended
above meter/regulator
assembly
3 ft (91 cm) within a
height 15 ft (4.5 m)
above the meter/regula-
tor assembly
3 ft (91 cm)
†
A vent shall not terminate directly above a sidewalk or paved driveway that is
located between two single family dwellings and serves both dwellings
$77(17,21 9LQ\O 6RI¿W 9LQ\O &HLOLQJ 9LQ\O 2YHUKDQJ
Disclaimer
Clearances are to heat resistant material (i.e. wood, metal). This
does not include vinyl. Empire Comfort Systems Inc. will not be held
responsible for heat damage caused from terminating under vinyl
RYHUKDQJVYLQ\OFHLOLQJVRUYLQ\OYHQWLODWHGXQYHQWLODWHGVRI¿WV
‡
Permitted only if veranda,, porch, deck, or balcony is fully open on a minimum
RIWZRVLGHVEHQHDWKWKHÀRRU
*
)RUFOHDUDQFHVQRWVSHFL¿HGLQ$16,=1)3$RU&6$%RQHRI
the following shall be indicated:
a)
A minimum clearance value determined by testing in accordance with section
2.23.5, or;
b)
A reference to the following footnote: “Clearance in accordance with local
LQVWDOODWLRQFRGHVDQGWKHUHTXLUHPHQWVRIWKHJDVVXSSOLHU´
Figure 8