TOP VENT - VERTICAL TERMINATION
No Elbows
Index
Letter
Dimensions
Maximum
Minimum
A
40 ft
10 ft
Figure 38
Two 90
Elbows
Dimensions (in Feet)
A
B*
MIN. 4
8
20
6
10
18-1/2
8
12
17
10
14
16
MAX. 12
16
15
*Maximum horizontal run is 100% of vertical, but cannot exceed
20 feet.
Figure 39
Three 90
Elbows
Note: Subtract 3ft (914 mm) from the total horizontal measure-
PHQW IRU HDFK HOERZ LQVWDOOHG KRUL]RQWDOO\ 6XEWUDFW IW
PPIURPWKHWRWDOKRUL]RQWDOPHDVXUHPHQWIRUHDFKHO
-
bow installed horizontally.
Dimensions (in Feet)
A
B*
MIN. 4
8
17
6
10
15-1/2
8
12
14
10
14
13
MAX. 12
16
12
*Maximum horizontal run is 100% of vertical, but cannot exceed
17 feet.
Figure 40
$IWHULQVWDOOLQJWKHYHQWV\VWHPLQVWDOOÀXHKHDWVKLHOG
+DQGEHQGWDEVRQÀXHKHDWVKLHOGRXW
2. Attach to insulation box as shown in Figure 41.
Figure 41 (vent pipe removed for clarity)