ELECTRICAL CONSIDERATIONS
CAUTION
$OOZLULQJVKRXOGEHGRQHE\DTXDOL¿HGHOHFWULFLDQDQGVKDOOEH
in compliance with all local, city and state building codes. Before
making the electrical connection, make sure the main power
supply is disconnected. The appliance, when installed, must be
electrically grounded in accordance with local codes, or in the
DEVHQFHRIORFDOFRGHVZLWKWKH1DWLRQDO(OHFWULFDO&RGH$16,
1)3$/DWHVW(GLWLRQ
ORANGE
PILOT
GAS CONTROL VALVE
ORANGE
GREEN
YELLOW
WHITE
BLACK
WHITE
OPTIONAL BLOWER
FUSE
BLACK
L
N
G
WHITE
GREEN
TO JUNCTION
BOX
AUX.
LOOP
RECEIVER MODULE
SPLIT FLOW SOLENOID
SLEEVE
USER INTERFACE/
BATTERY HOLDER
LEARN
BUTTON
IGNITOR
FLAME SENSOR
3.15
AMP
7KHXVHULQWHUIDFHEDWWHU\KROGHUPXVWEHPRXQWHGZLWKLQDGLVWDQFH
allowed by the attached 12 foot harness. As shipped, this harness is
already fed through a strain relief on the bottom of the component
DFFHVVER[DQGLVDWWDFKHGWRWKH8VHU,QWHUIDFH%DWWHU\+ROGHU
NOTE:
If an auxiliary device is to be used, its wiring may be fed
through the junction box strain relief. Auxiliary device amperage
limit is 5 amps.
NOTE:
A one inch diameter hole should be use to pass wiring through
studs.
VERTICAL
FRAMING
MEMBER
USER INTERFACE
HARNESS
USER INTERFACE/
BATTERY HOLDER
MUST BE INSTALLED
INTO WALL JUNCTION
BOX. (ORANGE LOW-
VOLTAGE BOX
RECOMMENDED.)
COMPONENT
ACCESS BOX
ELECTRICAL POWER TO UNIT
JUNCTION BOX / CONTROL MODULE
Figure 13
Figure 14
A factory installed junction box is located on the lower right side of
WKH¿UHSODFH:LULQJPXVWEHIHGWRWKHMXQFWLRQER[DQGDWWDFKHG
with wire nuts to the control module power leads already fed into
the junction box.
Attach black to black and white to white. The ground wire should
be attached to the green control module lead.