background image

20101-5-0509

Page 5

smoke will occur.  To prevent triggering of smoke alarms, ventilate 

the room in which the unit is installed.

Installation on Rugs and Tile

If  this  appliance  is  installed  directly  on  carpeting,  tile  or  other 

combustible material other than wood flooring the appliance shall 

be installed on a metal or wood panel extending the full width and 

depth of the appliance.  

The base referred to above does not mean the fire-proof base as 

used on wood stoves.  The protection is for rugs that are extremely 

thick and light colored tile.

Solid-fuels shall not be burned in a masonry or 

UL 127

 factory-

built fireplace in which an unvented room heater is installed.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment  

or  accessories  and  repair  and  servicing  of  equipment  shall  be 

performed only by a  qualified agency.  The term "qualified agency" 

means any individual, firm, corporation or company which either in 

person or through a representative is engaged in and is responsible 

for  (a)  the  installation  or  replacement  of  gas  piping  or  (b)  the 

connection, installation, repair or servicing of equipment, who is 

experienced in such work, familiar with all precautions required 

and has complied with all the requirements of the authority having 

jurisdiction.

State  of  Massachusetts:  The  installation  must  be  made  by 

a  licensed  plumber  or  gas  fitter  in  the  Commonwealth  of 

Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental 

room heaters shall provide to each purchaser a copy of 527 

CMR 30 upon sale of the unit.
In  the  Sate  of  Massachusetts,  unvented  propane  and  natural 

gas-fired  space  heaters  shall  be  prohibited  in  bedrooms  and 

bathrooms.

The installation must conform with local codes or, in the absence 

of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc.  1430 Broadway, 

New York, N.Y. 10018.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), ratings should be 

reduced at the rate of 4 percent for each 1,000 feet (305m) above 

sea level. Contact the manufacturer or your gas company before 

changing spud/orifice size.

Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect the 

Btu output of the unit. Contact the gas company for the heating 

value.  Contact  the  manufacturer  or  your  gas  company  before 

changing spud/orifice size.

WARNING:

  This  appliance  is  equipped  for  (natural  gas  or 

propane) gas. Field conversion is not permitted.

Instructions to Installer

1.  Installer  must  leave  instruction  manual  with  owner  after 

installation.

2.  Installer must have owner fill out and mail warranty card supplied 

with unvented room heater.

3.  Installer should show owner how to start and operate unvented 

room heater.

Always  consult  your  local  Building  Department    regarding 

regulations, codes or ordinances which apply to the installation of 

an unvented room heater.
This appliance may be installed in an  aftermarket* manufactured 

(mobile) home, where not prohibited by state or local codes.
*Aftermarket:  Completion of sale, not for purpose of resale, from 

the manufacturer.

This appliance is only for use with the type of gas indicated on 

the rating plate.  This appliance is not convertible for use with 

other gases.

WARNING:  ANY CHANGE TO THIS  HEATER  OR ITS 

CONTROLS CAN BE DANGEROUS.  

Improper installation or use of the heater can cause serious 

injury  or  death  from  fire,  burns,  explosion  or  carbon 

monoxide poisoning.

This  series  is  design  certified  in  accordance  with  American 

National Standard Z21.11.2  by the Canadian Standards Association 

Laboratories as an Unvented Room Heater and should be installed 

according to these instructions.

Any alteration of the original design, installed other than as 

shown in these instructions or use with a type of gas not shown on 

the rating plate is the responsibility of the person and company 

making the change.
VFp(32,36)Fp(30,31)L Only

750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts 

(electrical current) which energizes the magnet in the gas valve. 

After 30 seconds to 1 minute time period you can release the gas 

control knob and the pilot will stay ON. Allow your pilot flame to 

operate an additional one (1) to two (2) minutes before you turn the 

gas control knob from the PILOT position to the ON position. This 

time period allows the millivolts (electrical energy) to build-up to 

a sufficient level allowing the gas control to operate properly. 

Important

All correspondence should refer to complete Model Number, Serial 

Number and type of gas.

Attention:  During initial use of ceramic log you will detect an 

odor as the ceramic log is cured.  Also, during the curing process 

the ceramic log will burn with a yellow flame.

Notice: 

 During initial firing of this unit, its paint will bake out, and 

INTRODUCTION

Summary of Contents for VFP32FP(20

Page 1: ...ermanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases The Vail Vent Free Gas Fireplaces Do not store or use gasoline or other flamma ble vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do...

Page 2: ...g Installation 13 Fireplace Framing and Installation 14 Placement of Glowing Embers and Lava Rock 15 Operation Instructions Flame Appearance 16 VFP 32 36 FP 30 31 L Lighting Instructions 17 VFP 32 36 FP 20 21 L Lighting Instructions 18 Pilot Flame Characteristics 19 20 Wiring 20 Maintenance 20 Troubleshooting 21 Parts List 22 Parts View 23 How To Order Repair Parts 23 Optional Variable Speed Blowe...

Page 3: ...hould stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the same room with the appliance Do not place clothing or other flammable material on or near the appliance Installation and repair should be done by a qualified service person This appliance should be inspected before use and at least annually by a professional service person More fr...

Page 4: ...erform service or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP Gas Odor fade due to oxidation by rust or adsorption on walls of newcylindersandtanks ispossible Therefore peopleshould be particularly alert and careful when new tanks or cylinders are placed in service Odor fade can occur in new tanks or reinstalled old tank...

Page 5: ...any for the heating value Contact the manufacturer or your gas company before changing spud orifice size WARNING This appliance is equipped for natural gas or propane gas Field conversion is not permitted Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installermusthaveownerfilloutandmailwarrantycardsupplied with unvented room heater 3 Installer ...

Page 6: ... Platinum Embers FBB4 Variable Speed Automatic Blower VPP32A VFP32FP Ceramic Aged Brick Liner VPP36A VFP36FP Ceramic Aged Brick Liner Accessories For VFP 32 36 FP 30 31 Only FRBC Battery Operated Remote Control FRBTC Battery Operated Remote Control w Thermostat FREC Electric Remote Control FWS Wall Switch TMV Wall Thermostat Millivolt Reed Switch TRW Remote Wall Thermostat FBB4 is standard install...

Page 7: ...applied to areas such as joints around window and door frames between sole plates and floors between wall ceiling joints between wall panels at penetrations for plumbing electrical and gas lines and at other openings Ifyourhomemeetsallofthethreecriteriaabove youmustprovide additional fresh air See Ventilation Air From Outdoors page 8 Determining if You Have a Confined or Unconfined Space Usethiswo...

Page 8: ...oom see option 3 Figure 1 Each ventilation grill or opening shall have a minimum free area of one square inch per 1 000 BTUH of the total input rating of the gas equipment in the confined space Figure 1 Warning Rework worksheet adding the space of the adjoiningunconfinedspace Thecombinedspacesmusthave enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Figure 2 P...

Page 9: ...l be resistant to the action of liquefied petroleum gases The gas lines must be checked for leaks by the installer This should be done with a soap solution watching for bubbles on all exposed connections and if unexposed a pressure test should be made Never use an exposed flame to check for leaks Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pr...

Page 10: ...einletpressure to the pressure regulator from a minimum of 7 0 w c 1 74kPa for the purpose of input adjustment to a maximum of 10 5 w c 2 615kPa VFP 32 36 FP 30 31 LP Propane gas will have a manifoldpressureapproximately10 0 w c 2 49kPa formaximum input or 4 9 w c 1 220kPa for minimum input at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11 0 w ...

Page 11: ...to the mantel of your fireplace This is a fire hazard Figure 6 No greeting cards stockings or ornamentation of any type should beplacedonorattachedtothefireplace Thisisaheatingappliance The flow of heat can ignite combustibles Figure 7 COMBUSTIBLE MATERIALS ...

Page 12: ...509 Page 12 JUNCTION BOX ASSEMBLY C Figure 8 VFP32FP VFP36FP A 34 39 B 29 34 C 17 3 8 17 3 8 D 31 36 E 22 7 8 24 7 8 F 32 3 4 34 3 4 G 44 7 16 48 H 44 7 16 48 I 55 7 8 60 7 8 J 35 3 4 37 3 4 FIREPLACE DIMENSIONS ...

Page 13: ... Replace top louver Figure 9 Finishing All joints top bottom and sides where the wall or decorative facing material meets the fireplace surround must be completely sealed with a non combustible material Hearth extensions are recommended not a requirement for these gas fireplaces Do not cover the louvers at any time with finishing materials This could cause this product to overheat and cause a fire...

Page 14: ...Nailing flanges should fit directly against framing material Use at least one 1 nail per tab to secure in place Attention Add 3 3 4 to A Dimensions when using flush mantel base Figure 12 Fireplace framing can be built before or after the fireplace is set in place Framing should be positioned to accommodate wall covering and fireplace facing material The fireplace framing should be constructed of 2...

Page 15: ...laced in the area of the pilot assembly Replacement of loose material glowing embers must be purchased from Empire Comfort Systems Inc Application of excess loose material glowing embers may adversely affect performance of the heater WARNING All previously applied loose material must be removed prior to reapplication Refer to Log Instruction Manual to order loose material rock wool Placing Lava Ro...

Page 16: ... and temporary occurrence The initial break in operation should last 2 3 hours with the burner at the highest setting Provide maximum ventilation by opening windows or doors to allow odors to dissipate Any odors remaining after this initial break in will be slight and will disappear with continued use PERIODIC CLEANING Refer to parts diagram for location of items discussed below Do not use cleanin...

Page 17: ... PILOT to OFF unless knob is pushed in slightly Do not force 6 Wait ten 10 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety informa tion above If you do not smell gas go to the next step 7 Find pilot Follow metal tube from gas control The pilot is behind the burner on the right side 8 Turn gas control knob counterclockwise to PI ...

Page 18: ...ition or gas flow to the appliance is shut off the pilot cannot be relighted until the safety magnet is de energized approximately 60 seconds There will be an audible click when the safety magnet in the gas control is de energized Pilot can now be relighted Repeat steps 4 through 8 10 Turn gas control knob counterclockwise to 5 11 Turn on all electric power to appliance if applicable 12 Set thermo...

Page 19: ... pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down VFP 32 36 FP 30 31 PILOT Correct Pilot Flame Pattern Figure 13 Incorrect Pilot Flame Pattern Figure 14 If pilot flame pattern is incorrect as shown in Figure 14 See Troubleshooting page 21 VFP 32 36 FP 20 21 Pilot Correct Pilot Flame Pattern Figure 15 Incorre...

Page 20: ... When facing the appliance the remote receiver must be placed to the right of the gas valve Install remote control receiver behind bottom louver Refer to remote control installation and operating instructions for more details on remote control Keep the control compartment logs and burner area surrounding the logs clean by vacuuming or brushing area at least twice a year THE LOGS CAN GET VERY HOT H...

Page 21: ...t Replace gas regulator 7 ODS pilot lights but flame goes out when control knob is released a Control knob not fully pressed in Press in control knob fully b Control knob not pressed in long enough After ODS pilot lights keep control knob pressed in 30 seconds c Manual Shutoff valve not fully open Fully open manual shutoff valve d Thermocouple connection loose at control valve Hand tighten until s...

Page 22: ...R5675 R5675 R5675 AIR SHUTTER FULLY OPEN LP UNITS 15 R5676 R5676 R5676 R5676 AIR SHUTTER NAT UNITS 16A R3623 R3623 PILOT ASSEMBLY LP 16A R3624 R3624 PILOT ASSEMBLY NAT 16B R5170 R5170 PILOT LP 16B R5171 R5171 PILOT NAT 17 20467 20467 20467 20467 PILOT SHIELD 18 17370 17370 17386 17386 BURNER ASSEMBLY 19 20091 20091 20138 20138 BURNER BASE PLATE ASSEMBLY 20A 17369 17369 TUBING ASSEMBLY 20B 20093 20...

Page 23: ...cription of each part from the following appropriate illustration and list Be sure to give all this information Fireplace Model Number Part Description Fireplace Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments contingent upon strikes fires and all causes be...

Page 24: ...t be centered with the back wall of the fireplace Place blower assembly against the back wall The magnets on the back and bottomofblowerassemblywillsufficientlyholdblowerassembly in place 5 Positionspeedcontrolboxtotherightofgasvalve Attachspeed control box to bottom of fireplace The magnets on the bottom of speed control will sufficiently hold the speed control box in place 6 Withbase flushface o...

Page 25: ...adapter and be electrically grounded CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Blower Motor The blower motor does not have oiling holes Do not attempt to oil the blower motor Blower Wheels The blower wheels will collect lint and could require periodic cleaning If the air ou...

Page 26: ...to opposite side of receptacle The ground wire should be attached to the green neutral screw Install the receptacle into the junction box Attach cover plate Brick Liner VPP32A and VPP36A 1 Remove screen from fireplace 2 Remove branch log and rear log from burner assembly 3 Insert back panel into firebox 4 Insert one 1 side panel into firebox 5 Use two 2 brick panel brackets to secure side panel Al...

Page 27: ...20101 5 0509 Page 27 SERVICE NOTES ...

Page 28: ...20101 5 0509 Page 28 Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH 618 233 7420 or 800 851 3153 FAX 618 233 7097 or 800 443 8648 info empirecomfort com www empirecomfort com ...

Reviews: