Page 23
15628-0-0903
Vertical Through the Roof Applications
Your Gas Fireplace has been approved for
a) Vertical installations up to 25 feet in height.
b) Two sets of 45 degree elbow offsets within these vertical
installations. From 0 to a maximum of 8 feet a vent pipe can
be used between elbows.
c) Wall straps must be used to support offset pipe every 4 feet.
This applications will require that you first determine the roof
pitch and use the appropriate venting components.
Reassembly and Resealing Vent-Air Intake System
Attach vent elbow to appliance air drop with (4) 1/2" hex-head
screws in either the vertical or horizontal position, replace
horizontal and vertical pipe lengths, elbows and horizontal or
vertical termination kit.
All vent system components lock into place by sliding the
concentric pipe section with four (4) equally spaced interior
beads onto the appliance collar or previously installed component
end with four (4) equally spaced indented sections. When the
internal beads of each starting 6-5/8 inch outer pipe line up, rotate
pipe section clockwise 90
°
(approximately 3 inches). The vent
pipe is now locked together.
Continue replacing components per the vent system configuration.
Be certain that each succeeding vent component is securely fitted
and locked into the preceding component in the vent system.
Installing Support Brackets
A horizontal pipe support MUST BE used for each 3 feet of
horizontal run. The pipe supports should be placed around 6-5/8
inch diameter pipe and nailed in place to framing members. There
MUST BE a 2 inch clearance to combustibles above 6-5/8 inch
diameter pipe and elbows and 1 inch clearance on both sides and
bottom of 6-5/8 inch to combustibles on all horizontal pipe
sections and elbows.
Vertical runs of this vent systems must be supported every 4 feet
above the appliance flue outlet by wall brackets attached to the 6-
5/8 inch vent pipe and secured with nails or screws to structural
framing members.
Figure 32
LOG PLACEMENT
1. Lower valve cover on firebox.
2. Release two door latches at bottom of firebox.
3. Grasp bottom of glass frame, lift glass frame upward in order
to release glass frame from lip on top of firebox.
4. Remove logs from interior of firebox. Remove all protective
packaging from logs and interior of firebox.
5. Place front log onto two (2) front pins on inner bottom.
6. Place rear log onto two (2) pins on rear log support.
7. Place top log onto two (2) pins on rear log.
8. Align and place top of glass frame over lip on top of firebox.
Grasp bottom of glass frame, push inward and place glass
frame onto firebox.
9. Attach two door latches to bottom of firebox.
10. Log placement is completed.
Refer to Figure 33 for the following warning.
Warning: Failure to position the parts in accordance with
this diagram or failure to use only parts specifically approved
with this appliance may result in property damage or personal
injury.
Avertissement: Risque de dommages ou de blessures si les
pièces ne sont pas installées conformément à ce schéma et ou
si de pièces autres que celles spécifiquement approuvées avec
cet appareil sont utilisées.
Figure 33