23835-4-0208
Page 34
NOTE:
Termination cap should pass through the wall firestop
from the exterior of the building. Adjust the termination
cap to its final exterior position on the building.
Warning: Termination cap must be positioned so that arrow
is pointing up.
Attach the termination cap with the four wood screws provided.
Before attachment of the termination, run a bead of silicone sealant
rated above 250°F on its outside edge too, so as to make a seal to
the exterior wall.
NOTE: Wood screws can and should be replaced with appropriate
fasteners for use on stucco, brick, concrete or other types
of siding.
CAUTION: If exterior walls are finished with vinyl siding, (or
materials that could become discolored or warp) it is necessary to
install a vinyl siding standoff.
The vinyl siding standoff will be installed between the vent
termination and the exterior wall.
See Figure 52.
This horizontal vent
termination bolts onto the flat portion of the vinyl siding standoff, so
an air space will exist between the wall and the termination cap.
BOLT (4 REQUIRED)
VENT TERMINATION
WOOD SCREWS (4 REQUIRED)
NUT
(4 REQUIRED)
CUT VINYL SIDING AWAY
TO FIT STANDOFF
Figure 52
HORIZONTAL TERMINATION