10
Worksheet for Re-Programming 7 Day and 5+1+1 Day Program
Cooling
Program
Wake Up
(Period 1)
Leave For Work
(Period 2)
Return Home
(Period 3)
Go To Bed
(Period 4)
MON
6:00 AM
75°F
8:00 AM
83°F
5:00 PM
75°F
10:00 PM
78°F
TUE
WED
THU
FRI
SAT
6:00 AM
75°F
8:00 AM
83°F
5:00 PM
75°F
10:00 PM
78°F
SUN
6:00 AM
75°F
8:00 AM
83°F
5:00 PM
75°F
10:00 PM
78°F
Heating
Program
Wake Up
(Period 1)
Leave For Work
(Period 2)
Return Home
(Period 3)
Go To Bed
(Period 4)
MON
6:00 AM
70°F
8:00 AM
62°F
5:00 PM
70°F
10:00 PM
62°F
TUE
WED
THU
FRI
SAT
6:00 AM
70°F
8:00 AM
62°F
5:00 PM
70°F
10:00 PM
62°F
SUN
6:00 AM
70°F
8:00 AM
62°F
5:00 PM
70°F
10:00 PM
62°F
PROGRAMMING
TROUBLESHOOTING
Comfort Alert Codes
The Comfort Alert diagnostics product monitors the air
conditioning outdoor systems with single phase Copeland
Scroll compressors. Abnormal system and electrical
conditions are indicated by flashing ALERT codes on the
yellow LED on the Comfort Alert module. The flash codes are
transmitted to the thermostat by the Comfort Alert Thermostat
interface module. The Comfort Alert compatible thermostat
displays
“Call For Service”
that flashes at the same rate as
the yellow LED on the Comfort Alert module.
Comfort Alert Yellow Alert Codes
1 Flash
Long run time
2 Flashs
System pressure trip
3 Flashs
Short cycling
4 Flashs
Locked rotor
5 Flashs
Open circuit
6 Flashs
Open start circuit
7 Flashs
Open run circuit
8 Flashs
Welded Contactor
9 Flashs
Low voltage