26
1F95-391
Press
TIME
FWD
and
TIME
BACK
at the same time to enter the configuration menu. Press
TIME
FWD
until you get to
°
C then press the
or
arrow to select
°
F, press
PROGRAM
RUN
to return to normal operation.
Press
PROGRAM
RUN
to make certain the thermostat is in the run program mode, then
to bypass the program and operate the thermostat manually press the
MODE
SYSTEM
button
to select Heat or Cool (whichever you prefer) and press
HOLD
. Use the
TEMP
or
TEMP
buttons to set the thermostat on the temperature you want. The temperature
setting you choose will be held until you manually change it using the
TEMP
or
TEMP
buttons. The thermostat will remain in the
HOLD
mode when you change
temperature and maintain whatever temperature you set. If you decide to return to the
program, press
PROGRAM
RUN
to cancel the hold feature.
FAQs
1. My thermostat is reading
Celsius. How do I change it
to Fahrenheit?
2. How do I bypass (not
use) the program?
Humidifier Control
and Monitoring
When the humidity button is pressed
while in the run mode and in the HEAT
position, the actual humidity will be
displayed on the left side of the
display.
HUMD
is displayed above
the actual humidity. The humidity set
point is displayed on the right side of
the display.
or
button
may be pressed to modify the humidity
set point (range 5 to 50). Maximum
displayed humidity is 97% RH and
minimum displayed humidity is 2%
RH. If the heating system is operating
and there is a demand for humidity,
then the humidifier will operate. If the
demand for humidity is not satisfied
for ten consecutive heat cycle
operations, the display will show the
word
HUMD
for one second and the
word
MX
for one second signaling
maximum possible humidity is
reached.
Summary of Contents for 1F95-391