Automatic Reporting
Automatic reporting is the process of having the seismograph send out a report string after a
waveform trigger, the closing of a histogram, at a fixed time of day, or at specified intervals.
Automatic reporting is normally used with remote monitoring. With a White approved
remote access device, the data can be forwarded to a network running our AutoReceive™
software. This software processes the incoming data and can be used to send notifications of
measurements by email and SMS. We offer our Reporting Service for customers who do not
wish to host their own.
The Pro can be programmed to output a report string under one of the following three
conditions:
Triggered Reporting
A report string is sent out after a triggered waveform event or at the closing of a histogram.
Fixed Reporting
A report string is sent out at a fixed time of day.
Interval Reporting
A report string is sent out at regular intervals.
Heartbeat
The Pro can also output a heartbeat at a specified time of day. The heartbeat is not a report.
Rather it is simply an indication that the unit is functioning.
The Command Terminal of the Seismograph Data Analysis software is used to program the
seismograph for automatic reporting. Please refer to this software.
Please note that the Pro is not supported by AutoReceive V2. Check with White for the
version of AutoReceive that supports the Pro.