background image

 

WHITEHALL MANUFACTURING

 

• P.O. BOX 3527 • City of Industry, CA 91744-0527 U.S.A Phone (800) 782-

7706 • (626) 968-6681 • Fax (626) 855-4862 • Web: www.whitehallmfg.com

 

Instructions for Operation and Care of Dickson Paraffin Baths

 

9

 

the fingertips to the first knuckle and waiting about ten seconds 
for  the  wax  to  cool.  Next,  dip  the  patient's  hand  from  the 
fingertips to the second knuckle (proceeding to cover up the first 
layer of wax and effectively insulating the hand from some of the 
heat).  Continue  to  build  the  wax  up  incrementally  by  small 
amounts.

 

OTHER USEFUL INFORMATION:

 

l

 

Model S is an old reference to current models PB-101 and

 

PB-107

 

l

 

Model K is an old reference to current model PB-104 

l

 

Model BB 

is an old reference to current model PB-105 

Model H (no longer 

being  manufactured)  is  referring  to  an  old  PB-104  without  a 

drain.

 

The  sanitize  mode  on  the  PB-104,  PB-105,  and  PB-107  are 

turned on with a timer.

 

The sanitize mode on a PB-101 is turned on with a three- way 

switch.

 

l

 

All Dickson models have a sanitizing circuit.

 

Standard operating temperature is 126° to 130°F (52.2° to 

 

54.4°C) 

Lowest operating temperature is 126°F or 52.2°C. 

Below this temperature, wax  will harden (if lid is removed from 
the unit or power is off)

 

A  capillary  thermostat  is  attached  to  the  temperature  control. 

This device controls the temperature with a mechanism that 
involves a tube filled with oil. The temperature heats up the 
oil    in the capillary, and the hotter it gets, the higher the oil 
rises up the tube.

 

There  are  2  overheating  sensors  in  all  models  except  for  the  

PB-101. The L-145 is the low limit overheating sensor. This 
sensor will turn the unit off when it gets in the range of 145° 
to 155°F (62.8 to 68.3°C). The other overheating sensor is for 
the  sanitize  mode.  This  sensor  will  not  allow  the  unit  to  go 
past 200°F or  93.3°C.

 

Timer  is  only  to  be  used  to  turn  on  the  sanitize  sequence  in 

which  the  temperature  of  the  wax  will  approach  200°F  or 
93.3°C. All units except for the PB-101 are simply turned on 
by plugging them in. The PB-101 has a switch.

 

PARTS LIST FOR DICKSON PARAFFIN BATHS   

 

 

 

 

 

 

 

 

 

 

 

 

WHITEHALL PART #

 

 

 

 

 

 

 

 

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

1

 

 

5902-111-399

 

 

Cover, Stainless Steel

 

 

x

 

 

x

 

 

 

 

 

 

x

 

 

x

 

 

 

 

 

 

2

 

 

6902-306-000

 

 

Cover, Plastic

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

x

 

 

 

 

3

 

 

6902-412-000

 

 

Cover, Plastic 

(Front Section)

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

x

 

 

4

 

 

6902-410-000

 

 

Cover, Plastic 

(Rear Section)

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

x

 

 

5

 

 

6902-308-000

 

 

Drain Insert 

 

 

 

 

 

 

x

 

 

x

 

 

 

 

 

 

x

 

 

x

 

 

6

 

 

6902-350-000

 

 

Drain Valve

 

 

 

 

 

 

x

 

 

x

 

 

 

 

 

 

x

 

 

x

 

 

7

 

 

6902-130-001

 

 

Element, Heating 120V

 

 

x

 

 

x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

6902-136-001

 

 

Element, Heating  220V

 

 

 

 

 

 

 

 

 

 

x

 

 

x

 

 

 

 

 

 

9

 

 

6902-327-000

 

 

Element, Heating 120V

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

6902-330-000

 

 

Element, Heating  220V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

 

 

11

 

 

6902-438-000

 

 

Element, Heating 120V

 

 

 

 

 

 

 

 

x

 

 

 

 

 

 

 

 

 

 

12

 

 

6902-439-000

 

 

Element, Heating 220V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

x

 

 

13

 

 

0710-230-001

 

 

Fuse Holder/Cap

 

 

x

 

 

x

 

 

x

 

 

x

 

 

x

 

 

x

 

 

x

 

 

x

 

 

Summary of Contents for Dickson PB-101

Page 1: ...INSTRUCTIONS FOR OPERATION AND CARE OF INSTITUTIONAL PARAFFIN BATH MODELS PB 101 PB 107 PB 104 PB 105 P O Box 3527 City of Industry CA 91744 0527 U S A 800 782 7706 626 968 6681 www whitehallmfg com...

Page 2: ...ater ELECTRICAL SHOCK HAZARD l NEVER use unit in the presence of combustible liquids or gases EXPLOSION HAZARD l AVOID TOUCHING BOTTOM OF TANK Bottom can be hotter than paraffin due to heating element...

Page 3: ...l eau RISQUE DE D CHARGES LECTRIQUES l NE JAMAIS utiliser l appareil pr s de liquides ou de gaz combustibles RISQUE D EXPLOSION l VITER DE TOUCHER LE FOND DU R SERVOIR Le fond peut tre plus chaud que...

Page 4: ......

Page 5: ...r PB 105 15 Wiring Diagram for PB 101 16 Wiring Diagram for PB 107 17 Wiring Diagram for PB 104 18 Wiring Diagram for PB 105 19 Warranty Info 20 WHY DICKSON PARAFFIN BATHS DICKSON Paraffin Baths are p...

Page 6: ...ing Found on models PB 104 PB 105 only These hard wood moldings with a new plastic epoxy finish insure the patient s protection from the heat of the bath and surrounding metal They are contoured and p...

Page 7: ...27 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffin Baths 3 DICKSON PARAFFIN BATH MODEL PB 101 High Heat Sanitizi...

Page 8: ...27 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffin Baths 4 DICKSON PARAFFIN BATH MODEL PB 107 High Heat Sanitizi...

Page 9: ...of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffin Baths 5 DICKSON PARAFFIN BATH MODEL PB...

Page 10: ...by a close differential thermo switch set to automatically keep the bath liquid at a temperature of 126 F 52 2 C The DICKSON Bath precisely maintains this temperature This insures the quickest possibl...

Page 11: ...input of the paraffin the bath must be used judiciously in treating old weak or debilitated individuals If circulatory and sensory changes are present the application of paraffin should be made cautio...

Page 12: ...lding to see if it has been tripped Third the green light may be broken For PB 104 PB 105 6902 135 000 and for the PB 101 PB107 6902 122 000 4 On off light is dark even though the paraffin bath is plu...

Page 13: ...off l A capillary thermostat is attached to the temperature control This device controls the temperature with a mechanism that involves a tube filled with oil The temperature heats up the oil in the...

Page 14: ...346 000 Light Rectangle Red 125VAC x x 21 6902 347 000 Light Rectangle Red 250VAC x x 22 6902 122 000 Light Square Green 125VAC x x 23 6902 119 000 Light Square Green 250VAC x x 24 6902 124 000 Light...

Page 15: ...6902 424 000 Slat Plexiglass x x 38 6505 520 000 Strain Relief x x x x x x x x 39 6902 126 000 Switch Temperature x x 40 6902 138 000 Thermometer x x x x 41 6902 139 000 Thermometer Celsius x x x x 4...

Page 16: ...MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffin Baths...

Page 17: ...ATH WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson P...

Page 18: ...ITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffi...

Page 19: ...ATH WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson P...

Page 20: ...ATH WHITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson P...

Page 21: ...ITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffi...

Page 22: ...ITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffi...

Page 23: ...ITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffi...

Page 24: ...ITEHALL MANUFACTURING P O BOX 3527 City of Industry CA 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Dickson Paraffi...

Page 25: ...damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of W...

Page 26: ...Member of...

Reviews: