background image

MANUFACTURER'S WARRANTY

Member of

Mailing Address:

P.O. Box 3527 • City of Industry, CA 91744-0527 U.S.A

Physical Address:

15125 Proctor Avenue • City of Industry, CA 91746 U.S.A

Phone 800-782-7706 • 626-968-6681

Fax 626-855-4862

Web: www.whitehallmfg.com 

E-mail: info@whitehallmfg.com 

Whitehall Manufacturing Company warrants that its products are free from defects in material or workmanship under 
normal use and service for a period of one year from date of shipment. Whitehall's liability under this warranty shall be 
discharged solely by replacement or repair of defective material, provided Whitehall is notified in writing within one 
year from date of shipment, F.O.B. Industry, California. 

This warranty does not cover installation or labor charges, and does not apply to materials which have been 
damaged by other causes such as mishandling or improper care or abnormal use.

 The repair or replacement of 

the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Whitehall under this 
warranty. Whitehall shall not be liable under any circumstances for incidental, consequential or direct charges caused 
by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other 
warranties expressed or implied. Product maintenance instructions are issued with each fixture, and disregard or non-
compliance with these instructions will constitute an abnormal use condition and void the warranty. Stainless steel 
must be properly maintained after the water has been introduced into the fixture, or Whitehall's limited warranty is void. 
If you have any questions or require technical assistance, please call 800-743-8219.

Go to 

 to fill out eWarranty Registration, keyword search: WARRANTY.

www.whitehallmfg.com

NOTICE TO KEEP ORIGINAL PACKAGING-

 Regarding warranty claims: customer must retain original packaging 

for one year upon receipt of product. If packaging is discarded, it is the customer's responsibility to provide adequate 
packaging. Any shipping claims that are a direct result of customer-provided packaging materials will be handled by 
the shipper.

Any questions regarding servicing of products in Europe or the Middle East should be directed to:

Acorn Powell, Limited • 5 Brearley Court, Baird Road Quedgeley, Gloucester GL2 2AF, United Kingdom 

Phone (44) 01452 721211 • Fax (44) 01452 721231 

Web www.acornpowell.co.uk

technicalsupport@acornpowell.co.uk

 

Summary of Contents for Dickson PB-104

Page 1: ...fg com 6900 189 000 INSTRUCTIONS FOR OPERATION AND CARE OF INSTITUTIONAL PARAFFIN BATH P O Box 3527 City of Industry CA 91744 0527 U S A Revised October 2018 PB 104 PB 104B PB 105 PB 105B Division of...

Page 2: ...nouvel appareil avant de l utiliser l EFFECTUER LA MISE LA TERRE de votre appareil DE FA ON APPROPRI E Brancher l appareil dans une prise disjoncteur diff rentiel de fuite la terre DDFT ce qui offre...

Page 3: ...Fuse 6 Wiring Diagram for PB 104 14 Wiring Diagram for PB 105 15 Warranty Info 16 Cleaning the Bath 6 Parts Diagram for PB 105 12 Wiring Diagram for PB 107 13 Paraffin Refills 6 Directions for Treatme...

Page 4: ...e the tank from the atmosphere and thereby minimize heat conduction and do contribute to the stability of the bath temperature These moldings in slightly extending over the inside of the tank also ser...

Page 5: ...ensions 14 1 2 L x 7 W x 10 D 368 L x 178 W x 254 D Tank Capacity 18 lbs 8 16 kgs Electrical Requirements Inlet Voltage 100 120 V Frequency 50 60 Hz 3 8 A Inlet Voltage 200 240 V Frequency 50 60 Hz 1...

Page 6: ...4 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODELS PB 105 PB 105B High Heat Sanitizing Indicator Light Low Heat Treatment Temperature Indicator Light High Hea...

Page 7: ...red 10 to 15 minutes for hands 15 to 30 minutes for arms Because of the high heat input of the paraffin the bath must be used judiciously If circulatory and sensory changes are present the application...

Page 8: ...Bath should be disconnected from the electrical outlet and the drain ring removed The sediment and sludge may then be drained the bottom flushed and the slats cleaned PARAFFIN REFILLS Whitehall Manufa...

Page 9: ...the wax up incrementally by small amounts 10 Old wax not melting properly and hardening over time after continual reuse There is a short circuit in the unit The unit must be opened up for repairs 9 Wa...

Page 10: ...ing x x 15 0710 216 001 Fuse 5 x 20mm 10A Fast Acting x x 16 0710 230 001 Fuse Holder 5 x 20mm x x x x x x 17 6900 130 000 Knob For Timer or Switch x x x x x x 18 6900 135 000 Light Rectangle Green 12...

Page 11: ...stor Assembly 12K 220V x 34 6902 470 001 Resistor Assembly 3K 120V x 35 6902 471 001 Resistor Assembly 12K 220V x 36 6902 374 000 Slat Plexiglass x x 37 6902 424 000 Slat Plexiglass x x 38 6505 546 00...

Page 12: ...A 91744 0527 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 10 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODEL PB 107 24 1 44...

Page 13: ...7 U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 11 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODEL PB 104 47 33 20 18 28 6 4...

Page 14: ...U S A Phone 800 782 7706 626 968 6681 Fax 626 855 4862 Web www whitehallmfg com 12 Instructions for Operation and Care of Dickson Paraffin Baths DICKSON PARAFFIN BATH MODEL PB 105 45 18 20 48 17 19 21...

Page 15: ...lmfg com 13 Instructions for Operation and Care of Dickson Paraffin Baths FUSE FUSE BLU BRN YEL GRN BLU BRN GND POWER INLET L N HEATING ELEMENT THERMOSTAT RED LIGHT TIMER CONTROL GREEN LIGHT L200 TWIS...

Page 16: ...B 104 FUSE 1 FUSE 2 BLK WHT YEL GRN WHT WHT GND POWER INLET SK RESISTOR GREEN LIGHT RED LIGHT BLK L N HEATING ELEMENT TIMER CONTROL BLK BLK BLK OPERATING THERMOSTAT LOW TEMP THERMOSTAT HIGH TEMP THERM...

Page 17: ...B 105 FUSE 1 FUSE 2 BLK WHT YEL GRN WHT WHT GND POWER INLET SK RESISTOR GREEN LIGHT RED LIGHT BLK L N HEATING ELEMENT TIMER CONTROL BLK BLK BLK OPERATING THERMOSTAT LOW TEMP THERMOSTAT HIGH TEMP THERM...

Page 18: ...r direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instruct...