background image

Whitehall Manufacturing Company warrants that its products are free from defects in material or workmanship under 
normal use and service for a period of one year from date of shipment. Whitehall's liability under this warranty shall be 
discharged solely by replacement or repair of defective material, provided Whitehall is notified in writing within one 
year from date of shipment, F.O.B. Industry, California.

This warranty does not cover installation or labor charges, and does not apply to materials which have been 
damaged by other causes such as mishandling or improper care or abnormal use.

 The repair or replacement of 

the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Whitehall under this 
warranty. Whitehall shall not be liable under any circumstances for incidental, consequential or direct charges caused 
by defects in the materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other 
warranties expressed or implied. Product maintenance instructions are issued with each fixture, and disregard or non-
compliance with these instructions will constitute an abnormal use condition and void the warranty. If you have any 
questions or require technical assistance, please call 800-743-8219.

NOTICE TO KEEP ORIGINAL PACKAGING-

 Regarding warranty claims: customer must retain original packaging 

for one year upon receipt of product. If packaging is discarded, it is the customer's responsibility to provide adequate 
packaging. Any shipping claims that are a direct result of customer-provided packaging materials will be handled by 
the shipper.

 

MANUFACTURER'S WARRANTY

Member of

Summary of Contents for E-27-S

Page 1: ...E 27 S S 90 S 6900 194 000 INSTRUCTIONS FOR OPERATION AND CARE OF Stationary Whirlpool Member of Revised February 2016...

Page 2: ...ed tested and certified as complying with all applicable European Union regulations and recommendations Waste Electrical and Electronic Equipment WEEE This symbol on the product or on its packaging in...

Page 3: ...age 12 Stationary P Series Page 13 Stationary S Series Page 14 Motor Raising Lowering Assembly Small Page 15 Motor Raising Lowering Assembly Page 16 Motor Raising Lowering Assembly Slant Back Page 17...

Page 4: ...ol free of excessive wear Does the turbine mount securely in place Is a properly grounded and voltage matched hospital grade receptacle available for the turbine Is the outlet or turbine cord equipped...

Page 5: ...safe practices for the patient and themselves If a turbine is used Plug the turbine cord only into a receptacle that is voltage matched properly grounded and polarized Verify that the receptacle has G...

Page 6: ...RECEPTACLE HOSPITAL ELECTRICAL REQUIREMENTS 8 AMPS 115 VOLTS GRADE WITH GROUND FAULT INTERRUPT FOR TURBINE 12 305 REC MIN 12 305 REC MIN B 521 4 1327 521 4 1327 B 43 4 120 A 1 ASSEMBLY 2 3 4 5 6 7 8...

Page 7: ...2 or 3 4 IPS H 75 S 42 1067 20 508 28 711 34 864 33 838 29 737 1 2 or 3 4 IPS H 90 S 48 1219 20 508 28 711 34 864 36 914 29 737 1 2 or 3 4 IPS H 105 S 48 1219 24 610 28 711 34 864 26 660 31 787 1 2 o...

Page 8: ...OL VALVE HANDLE 11 FULLY LIFT COMBINATION DRAIN OVERFLOW ASSEMBLY HANDLE 15 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY TURN...

Page 9: ...TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY TURN HANDLE 15 CLOCKWISE TO OPEN DRAIN VALVE 16 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSE...

Page 10: ...COMBINATION DRAIN OVERFLOW ASSEMBLY HANDLE 15 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY TURN ON THE SWITCH 13 TURN THE PRE...

Page 11: ...1 4 20 x 5 8 PHIL PAN HEAD SCREW 7 6502 300 000 8 32 x 3 8 PHIL FLAT HEAD SELF TAPPING 8 6525 514 199 SHAFT BEARING 9 6502 410 000 1 4 20 x 1 4 DOG SET SCREW 10 6502 352 000 3 8 16 x 3 HEX CAP SCREW 1...

Page 12: ...ASSY E 45 115VAC 60Hz 1L 6525 166 001 TURBINE ASSY E 45 230VAC 60Hz 1M 6525 167 001 TURBINE ASSY E 45 230VAC 50Hz 2A 6525 525 001 PLUNGER ASSY 12 E 15 S 2B 6525 528 001 PLUNGER ASSY 15 1 4 E 22 S 2C...

Page 13: ...H 105 M SDP DD 4828 DD 3628 1A 6525 168 001 TURBINE ASSY H 60 75 90 105 115VAC 60Hz 1B 6525 169 001 TURBINE ASSY H 60 75 90 105 230VAC 60Hz 1C 6525 170 001 TURBINE ASSY H 60 75 90 105 230VAC 50Hz 2 6...

Page 14: ...L 90 M SDP L 105 M SDP DD 6018 DD 6618 1A 6525 158 001 TURBINE ASSY L 75 90 105 115VAC 60Hz 1B 6525 159 001 TURBINE ASSY L 75 90 105 230VAC 60Hz 1C 6525 160 001 TURBINE ASSY L 75 90 105 230VAC 50Hz 2...

Page 15: ...230VAC 50Hz 1G 6528 108 001 TURBINE ASSY P 22 115VAC 60Hz 1H 6528 109 001 TURBINE ASSY P 22 230VAC 60Hz 1J 6528 110 001 TURBINE ASSY P 22 230VAC 50Hz 2A 6528 522 001 PLUNGER ASSY 9 1 2 P 10 2B 6528 5...

Page 16: ...DP S 90 M SDP S 110 M SDP 1A 6525 165 001 TURBINE ASSY S 85 90 110 115VAC 60Hz 1B 6525 166 001 TURBINE ASSY S 85 90 110 230VAC 60Hz 1C 6525 167 001 TURBINE ASSY S 85 90 110 230VAC 50Hz 2 6525 535 001...

Page 17: ...509 205 199 1 1 8 DIA x 12 1 8 TUBE P 10 S 2B 6509 215 199 1 1 8 DIA x 18 TUBE P E 15 S 2C 6509 215 199 1 1 8 DIA x 18 TUBE P E 22 MU SP 2D 6509 225 199 1 1 8 DIA x 20 TUBE P E 22 S 3A 6503 005 000 7...

Page 18: ...L 75 90 105 S 1E 6530 210 001 1 DIA R L ASSY L 75 90 105 M SL 1F 6530 225 001 1 DIA R L ASSY E 45 SL S 85 90 110 M SL 2A 6509 265 199 1 3 8 DIA x 23 1 2 TUBE E 27 S 2B 6509 275 199 1 3 8 DIA x 27 1 4...

Page 19: ...99 LOCKING HUB 4 6530 114 199 3 8 16 UNC STUD 5 6530 112 199 BUSHING 6 6530 111 199 LOCKING HANDLE 7 0116 104 000 1 4 20 x 1 2 PHILLIPS ROUND HEAD SCREW 8 6530 310 199 END CAP 9 6530 520 000 1 4 20 ST...

Page 20: ...GASKET 8 6508 050 199 STRAINER 9 6508 010 199 DRAIN TEE 10 6509 375 199 2 O D x 24 DRAIN TUBE SPORTS 11 6531 056 001 33 1 4 OVERFLOW ASSEMBLY HI BOY 12 6531 055 001 29 5 8 OVERFLOW ASSEMBLY 13 6531 10...

Page 21: ...Y E 22 SP 8B 6531 054 001 26 OVERFLOW ASSEMBLY E 27 S 8C 6531 055 001 29 5 8 OVERFLOW ASSEMBLY E 45 S 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PAN HEAD PHILLIPS SCREW 11 6531 110 001 FRICTION...

Page 22: ...D x 17 DRAIN TUBE L 75 90 105 S 8 6531 052 001 22 1 2 OVERFLOW ASSEMBLY 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PHILLIPS PAN HEAD SCREW 11 6531 110 001 FRICTION LOCK ASSEMBLY 12 6531 100 199...

Page 23: ...15 S 8C 6531 052 001 22 1 2 OVERFLOW ASSEMBLY E P 22 S 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PHILLIPS PAN HEAD SCREW 11 6531 110 001 FRICTION LOCK ASSEMBLY 12 6531 100 199 OVERFLOW BRACE 13...

Page 24: ...111 199 FRICTION LOCK ROD 15 6531 113 000 SPRING 16 6531 112 199 TENSION ADJUSTER 17 6531 101 199 COLLAR UPSTOP OVERFLOW 7 6508 010 199 DRAIN TEE 18 WHR00047 001 23 3 8 OVERFLOW TUBE ASSEMBLY 8 6509...

Page 25: ...2 O D ANGLED DRAIN TUBE P E 15 22 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7 6509 600 199 DRAIN ROD P 10 S P E 15 S 8 6509 601 199 DRAIN ROD P E 22 S 9 6531 330 000 STRAINER ASSY FOR SDO BURN TANKS 10 6...

Page 26: ...IN TUBE E 45 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7A 6509 602 199 DRAIN ROD E 22 SP 7B 6509 603 199 DRAIN ROD E 27 S 7C 6509 604 199 DRAIN ROD E 45 S 8 6531 330 000 STRAINER FOR SDO BURN TANK ASSEMBL...

Page 27: ...D DRAIN TUBE S 85 S 5E 6531 407 199 2 O D x 21 1 4 DRAIN TUBE S 90 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7 6509 605 199 DRAIN ROD H 60 75 90 S 8 6509 604 199 DRAIN ROD S 85 90 S 9 6531 330 000 STRAINE...

Page 28: ...STAINLESS STEEL HEX HD BOLT 4 6504 506 000 DRAIN VALVE GASKET 5 6531 323 000 WAFER BUTTERFLY VALVE 6 6531 332 199 VALVE COUPLING 7 6502 402 000 5 16 18 x 1 4 HEX SOCKET SET SCREW 8 6531 320 199 DRAIN...

Page 29: ...ETER 21 2B 6532 075 000 BOTTOM CONNECTED THERMOMETER 25 2C 6532 080 000 BOTTOM CONNECTED THERMOMETER 28 3 6502 451 000 10 32 x 1 4 PAN HD SLOTTED NYLON SCREW 4 6532 100 199 UPPER THERMOMETER BRACKET 5...

Page 30: ...with a mixture of suitable disinfectant solution per manufacture s recommended use Exposed surfaces should remain wet for at least 10 minutes 6 Drain the turbine bucket into the tank and open drain 7...

Page 31: ...LAZE STAINLESS STEEL Protecting the powder coated surface in keeping an Whitehall Enviro Glazed stainless steel product For normal wipe down cleaning a mild soap and a sponge or cotton cloth will perf...

Page 32: ...te The thermometer gauges temperatures from 40 to 140 F Do not allow temperatures to exceed 140 to avoid damaging the thermometer To recalibrate Immerse the stem a minimum of 4 into the water turn on...

Page 33: ...or Assemblies Motor Capacitor Assembly Condenser Cover Motor Base WHT BLK YEL GRN GND POWER INLET L N 6 1 2 1 MOTOR 2 1 X E BLU BRN YEL GRN GND POWER INLET L N 6 1 2 1 MOTOR 2 1 X E SWITCH SWITCH MOTO...

Page 34: ...under this warranty Whitehall shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement t...

Reviews: