background image

General Knowledge

2

TRAINING

Operator trainees need to:

Ÿ

be trained in aquatic-therapy protocols.

Ÿ

be  familiar  with  the  types  of  patients  who  should  or 

should  not  receive  this  type  of  physical  therapy  (see 
Patient Evaluation, below).

Ÿ

read  and  understand  this  manual  (and  the  manual  for 

the turbine, if used).

Ÿ

be  trained  on  the  use  of  the  whirlpool  (and  turbine,  if 

used).

Ÿ

practice  with  the  whirlpool  (and  turbine,  if  used)  before 

use with patient.

OPERATOR SKILLS AND TRAINING

Skills:

Operators using the whirlpool need:

Ÿ

a  working  knowledge  of  aquatic  physical-therapy 

procedures.

Ÿ

the ability to assist the patient.

PATIENT EVALUATION

Require Each Patient To Be Evaluated

 

or  patients  with 

certain other medical, mental or physical conditions should 
not receive treatment with the whirlpool.

The  trained  operator  must  evaluate  and  verify  that  each 
patient  is  suitable  for  hydrotherapy  treatment  before 
permitting  the  patient  to  begin  hydrotherapy.  If  in  doubt, 
consult  a  medical  professional  before  providing 
hydrotherapy treatment.

Patients  who  are  electrically-susceptible  (patients  with 
exposed,  non-waterproof  electric  leads,  monitors,  etc.), 
patients  carrying  infectious  disease, 

WARNING

!

INSPECTING THE WHIRLPOOL

Have  your  facility's  equipment  maintenance  personnel 
inspect the whirlpool regularly. Follow the checklist at right 
and  operate  the  whirlpool  through  all  its  functions  as 
described in this manual.

Inspection Checklist

Are all components present?

Is the whirlpool free of excessive wear?                                     

Does the turbine mount securely in place?

Is  a  properly-grounded  and  voltage-matched 

hospital grade receptacle available for the turbine?

Is  the  outlet  or  turbine  cord  equipped  with  a 

functioning GFI (or RCD)?

Can the turbine be raised, lowered and locked at the 

desired height?

Does the drain valve open and close properly?

Is the thermometer present and is it legible?

Do the installed accessories operate without 

interfering with whirlpool use or turbine operation?

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Ÿ

Important

BLOODBORNE DISEASE NOTICE:

 To reduce the 

risk of exposure to bloodborne diseases such as HIV-1 
and hepatitis when using the whirlpool, read and 
follow the disinfecting and cleaning instructions in this 
manual thoroughly.

Certain medical conditions are incompatible with 
hydrotherapy. The trained operator is responsible for 
determining each user’s suitability for hydrotherapy 
before beginning treatment.

WARNING

!

WARNING

!

Untrained operators can cause injury or be injured. 
Permit only trained personnel should operate the 
whirlpool.

WARNING

!

This Whitehall product has been carefully packaged at the 
factory to minimize the possibility of damage during 
shipping.

 Inspect the packaging for external signs of damage.

 Inspect the contents for damage.

If there is visible damage to the instrument upon receipt, 
inform the shipping company and Whitehall immediately.

WARNING

!

Do not attempt to operate this equipment if there is 
evidence of shipping damage or you suspect the unit 
is damaged. Damaged equipment may present 
additional hazards to you. Contact Whitehall technical 
support for advice before attempting to plug in and 
operate damaged equipment. 

WARNING

!

Summary of Contents for E-27-S

Page 1: ...E 27 S S 90 S 6900 194 000 INSTRUCTIONS FOR OPERATION AND CARE OF Stationary Whirlpool Member of Revised February 2016...

Page 2: ...ed tested and certified as complying with all applicable European Union regulations and recommendations Waste Electrical and Electronic Equipment WEEE This symbol on the product or on its packaging in...

Page 3: ...age 12 Stationary P Series Page 13 Stationary S Series Page 14 Motor Raising Lowering Assembly Small Page 15 Motor Raising Lowering Assembly Page 16 Motor Raising Lowering Assembly Slant Back Page 17...

Page 4: ...ol free of excessive wear Does the turbine mount securely in place Is a properly grounded and voltage matched hospital grade receptacle available for the turbine Is the outlet or turbine cord equipped...

Page 5: ...safe practices for the patient and themselves If a turbine is used Plug the turbine cord only into a receptacle that is voltage matched properly grounded and polarized Verify that the receptacle has G...

Page 6: ...RECEPTACLE HOSPITAL ELECTRICAL REQUIREMENTS 8 AMPS 115 VOLTS GRADE WITH GROUND FAULT INTERRUPT FOR TURBINE 12 305 REC MIN 12 305 REC MIN B 521 4 1327 521 4 1327 B 43 4 120 A 1 ASSEMBLY 2 3 4 5 6 7 8...

Page 7: ...2 or 3 4 IPS H 75 S 42 1067 20 508 28 711 34 864 33 838 29 737 1 2 or 3 4 IPS H 90 S 48 1219 20 508 28 711 34 864 36 914 29 737 1 2 or 3 4 IPS H 105 S 48 1219 24 610 28 711 34 864 26 660 31 787 1 2 o...

Page 8: ...OL VALVE HANDLE 11 FULLY LIFT COMBINATION DRAIN OVERFLOW ASSEMBLY HANDLE 15 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY TURN...

Page 9: ...TURN THE PRESSURE CONTROL VALVE HANDLE 11 FULLY TURN HANDLE 15 CLOCKWISE TO OPEN DRAIN VALVE 16 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSE...

Page 10: ...COMBINATION DRAIN OVERFLOW ASSEMBLY HANDLE 15 TURN OFF SWITCH 13 ADJUST PRESSURE CONTROL VALVE 11 TO DELIVER DESIRED ADJUST RAISING AND LOWERING ASSEMBLY 4 BY SLOWLY TURN ON THE SWITCH 13 TURN THE PRE...

Page 11: ...1 4 20 x 5 8 PHIL PAN HEAD SCREW 7 6502 300 000 8 32 x 3 8 PHIL FLAT HEAD SELF TAPPING 8 6525 514 199 SHAFT BEARING 9 6502 410 000 1 4 20 x 1 4 DOG SET SCREW 10 6502 352 000 3 8 16 x 3 HEX CAP SCREW 1...

Page 12: ...ASSY E 45 115VAC 60Hz 1L 6525 166 001 TURBINE ASSY E 45 230VAC 60Hz 1M 6525 167 001 TURBINE ASSY E 45 230VAC 50Hz 2A 6525 525 001 PLUNGER ASSY 12 E 15 S 2B 6525 528 001 PLUNGER ASSY 15 1 4 E 22 S 2C...

Page 13: ...H 105 M SDP DD 4828 DD 3628 1A 6525 168 001 TURBINE ASSY H 60 75 90 105 115VAC 60Hz 1B 6525 169 001 TURBINE ASSY H 60 75 90 105 230VAC 60Hz 1C 6525 170 001 TURBINE ASSY H 60 75 90 105 230VAC 50Hz 2 6...

Page 14: ...L 90 M SDP L 105 M SDP DD 6018 DD 6618 1A 6525 158 001 TURBINE ASSY L 75 90 105 115VAC 60Hz 1B 6525 159 001 TURBINE ASSY L 75 90 105 230VAC 60Hz 1C 6525 160 001 TURBINE ASSY L 75 90 105 230VAC 50Hz 2...

Page 15: ...230VAC 50Hz 1G 6528 108 001 TURBINE ASSY P 22 115VAC 60Hz 1H 6528 109 001 TURBINE ASSY P 22 230VAC 60Hz 1J 6528 110 001 TURBINE ASSY P 22 230VAC 50Hz 2A 6528 522 001 PLUNGER ASSY 9 1 2 P 10 2B 6528 5...

Page 16: ...DP S 90 M SDP S 110 M SDP 1A 6525 165 001 TURBINE ASSY S 85 90 110 115VAC 60Hz 1B 6525 166 001 TURBINE ASSY S 85 90 110 230VAC 60Hz 1C 6525 167 001 TURBINE ASSY S 85 90 110 230VAC 50Hz 2 6525 535 001...

Page 17: ...509 205 199 1 1 8 DIA x 12 1 8 TUBE P 10 S 2B 6509 215 199 1 1 8 DIA x 18 TUBE P E 15 S 2C 6509 215 199 1 1 8 DIA x 18 TUBE P E 22 MU SP 2D 6509 225 199 1 1 8 DIA x 20 TUBE P E 22 S 3A 6503 005 000 7...

Page 18: ...L 75 90 105 S 1E 6530 210 001 1 DIA R L ASSY L 75 90 105 M SL 1F 6530 225 001 1 DIA R L ASSY E 45 SL S 85 90 110 M SL 2A 6509 265 199 1 3 8 DIA x 23 1 2 TUBE E 27 S 2B 6509 275 199 1 3 8 DIA x 27 1 4...

Page 19: ...99 LOCKING HUB 4 6530 114 199 3 8 16 UNC STUD 5 6530 112 199 BUSHING 6 6530 111 199 LOCKING HANDLE 7 0116 104 000 1 4 20 x 1 2 PHILLIPS ROUND HEAD SCREW 8 6530 310 199 END CAP 9 6530 520 000 1 4 20 ST...

Page 20: ...GASKET 8 6508 050 199 STRAINER 9 6508 010 199 DRAIN TEE 10 6509 375 199 2 O D x 24 DRAIN TUBE SPORTS 11 6531 056 001 33 1 4 OVERFLOW ASSEMBLY HI BOY 12 6531 055 001 29 5 8 OVERFLOW ASSEMBLY 13 6531 10...

Page 21: ...Y E 22 SP 8B 6531 054 001 26 OVERFLOW ASSEMBLY E 27 S 8C 6531 055 001 29 5 8 OVERFLOW ASSEMBLY E 45 S 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PAN HEAD PHILLIPS SCREW 11 6531 110 001 FRICTION...

Page 22: ...D x 17 DRAIN TUBE L 75 90 105 S 8 6531 052 001 22 1 2 OVERFLOW ASSEMBLY 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PHILLIPS PAN HEAD SCREW 11 6531 110 001 FRICTION LOCK ASSEMBLY 12 6531 100 199...

Page 23: ...15 S 8C 6531 052 001 22 1 2 OVERFLOW ASSEMBLY E P 22 S 9 6531 102 199 HANDLE 10 6502 450 000 8 32 x 3 8 PHILLIPS PAN HEAD SCREW 11 6531 110 001 FRICTION LOCK ASSEMBLY 12 6531 100 199 OVERFLOW BRACE 13...

Page 24: ...111 199 FRICTION LOCK ROD 15 6531 113 000 SPRING 16 6531 112 199 TENSION ADJUSTER 17 6531 101 199 COLLAR UPSTOP OVERFLOW 7 6508 010 199 DRAIN TEE 18 WHR00047 001 23 3 8 OVERFLOW TUBE ASSEMBLY 8 6509...

Page 25: ...2 O D ANGLED DRAIN TUBE P E 15 22 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7 6509 600 199 DRAIN ROD P 10 S P E 15 S 8 6509 601 199 DRAIN ROD P E 22 S 9 6531 330 000 STRAINER ASSY FOR SDO BURN TANKS 10 6...

Page 26: ...IN TUBE E 45 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7A 6509 602 199 DRAIN ROD E 22 SP 7B 6509 603 199 DRAIN ROD E 27 S 7C 6509 604 199 DRAIN ROD E 45 S 8 6531 330 000 STRAINER FOR SDO BURN TANK ASSEMBL...

Page 27: ...D DRAIN TUBE S 85 S 5E 6531 407 199 2 O D x 21 1 4 DRAIN TUBE S 90 S 6 6531 325 001 DRAIN VALVE ASSEMBLY 7 6509 605 199 DRAIN ROD H 60 75 90 S 8 6509 604 199 DRAIN ROD S 85 90 S 9 6531 330 000 STRAINE...

Page 28: ...STAINLESS STEEL HEX HD BOLT 4 6504 506 000 DRAIN VALVE GASKET 5 6531 323 000 WAFER BUTTERFLY VALVE 6 6531 332 199 VALVE COUPLING 7 6502 402 000 5 16 18 x 1 4 HEX SOCKET SET SCREW 8 6531 320 199 DRAIN...

Page 29: ...ETER 21 2B 6532 075 000 BOTTOM CONNECTED THERMOMETER 25 2C 6532 080 000 BOTTOM CONNECTED THERMOMETER 28 3 6502 451 000 10 32 x 1 4 PAN HD SLOTTED NYLON SCREW 4 6532 100 199 UPPER THERMOMETER BRACKET 5...

Page 30: ...with a mixture of suitable disinfectant solution per manufacture s recommended use Exposed surfaces should remain wet for at least 10 minutes 6 Drain the turbine bucket into the tank and open drain 7...

Page 31: ...LAZE STAINLESS STEEL Protecting the powder coated surface in keeping an Whitehall Enviro Glazed stainless steel product For normal wipe down cleaning a mild soap and a sponge or cotton cloth will perf...

Page 32: ...te The thermometer gauges temperatures from 40 to 140 F Do not allow temperatures to exceed 140 to avoid damaging the thermometer To recalibrate Immerse the stem a minimum of 4 into the water turn on...

Page 33: ...or Assemblies Motor Capacitor Assembly Condenser Cover Motor Base WHT BLK YEL GRN GND POWER INLET L N 6 1 2 1 MOTOR 2 1 X E BLU BRN YEL GRN GND POWER INLET L N 6 1 2 1 MOTOR 2 1 X E SWITCH SWITCH MOTO...

Page 34: ...under this warranty Whitehall shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement t...

Reviews: