THERMOSTAT INSTALLATION:
NOTE: Always Disconnect Power Before Performing The Thermostat Installation.
A 24 volt wall thermostat and 20 feet of 18-gage thermostat wire is included in your stoves accessory package. It is rec-
ommended that the thermostat and thermostat wire be installed by an authorized Lennox Hearth Products dealer.
Installation Steps:
1. Unplug stove power cord from the wall outlet.
2. Locate the thermostat terminal block (see illustrations below).
3. Loosen the two terminal screws on the terminal block and remove the jumper.
4. Connect the two wires from your thermostat to the terminals (one per terminal). Ensure that the purple wires from the
harness remain connected to the terminal block and tighten the terminal screws. Make sure the wires are firmly con-
nected to the thermostat.
5. Plug in the stove and you are ready to operate with your thermostat!
IMPORTANT: IF THE WALL THERMOSTAT PROVIDED IS NOT USED, THE JUMPER IS REQUIRED FOR THE
STOVE TO OPERATE.
PAGE 13
Terminal Block for Thermostat
Leave Jumper on, If Thermostat Is Not Used
Remove Jumper if Thermostat Is To Be Used
Model: Optima 3 FS
Model: Optima 3 INS
(on right side of insert when viewed from the front)
Th
Model: Optima 2 FS
(viewed from stove back)
Jumper
Terminal Block
for Thermostat
Terminal Block
for Thermostat
Terminal Block
for Thermostat
Power Cord
Connector
Power Cord
Connector
Power Cord
Connector
Summary of Contents for Advantage Optima 2 FS
Page 38: ...WIRING DIAGRAM PAGE 38 ...
Page 44: ...REPLACEMENT PARTS DIAGRAMS PAGE 44 5 6 8 10 13 14 9 12 7 11 ...
Page 45: ...REPLACEMENT PARTS DIAGRAMS PAGE 45 15 16 17 19 20 22 24 25 26 27 18 23 ...
Page 46: ...REPLACEMENT PARTS DIAGRAMS PAGE 46 30 37 38 40 41 29 28 33 34 39 31 32 35 ...
Page 47: ...REPLACEMENT PARTS DIAGRAMS PAGE 47 43 44 45 46 47 42 ...
Page 49: ...INSTALLATION TIPS PAGE 49 ...