INSTALLATION
PAGE 16
DETERMINING SIZE OF PIPE TO INSTALL
To determine what diameter pipe to use in an installation (3” or 4”), first find the “equivalent pipe length” using the follow-
ing guidelines, then plot this figure and the altitude on the chart.
Fill out the installation chart, and calculate your total equivalent pipe length. After you have the total equivalent pipe
length, use the
Pipe Selection Chart
below to determine if your installation requires 3” or 4” exhaust pipe
.
INSTALLATION CHART
Type of
Pipe
# of Elbows
or Feet of
pipe
Equivalent
Feet
Total
Equivalent
Feet
90
o
Elbows /
Tee (A & G)
x
5 Ft. (1.5m)
45
o
Elbows (C)
x
3 Ft. (1m)
Horizontal
(B & F)
x
1 Ft. (.3m)
Vertical
(E)
x
.5
Ft.
(.15m)
A- 90 Degree Elbow
E- 8’ Vertical Pipe
B- 1’ Horizontal Pipe
F- 2’ Horizontal Pipe
C- 45 Degree Elbow
G- 90 Degree Tee
D- Standoff Braces
H- Wall Thimble
NOTE: All equivalent pipe styles shown to the right are
standard for all freestanding models.
SAMPLE INSTALLATION CHART
Type of
Pipe
# of Elbows
or Feet of
pipe
Equivalent
Feet
Total
Equivalent
Feet
90
o
Elbows /
Tee (A & G)
2
x
5 Ft. (1.5m)
10 (3m)
45
o
Elbows (C)
1
x
3 Ft. (1m)
3 (1m)
Horizontal
(B & F)
3
x
1 Ft. (.3m)
3 (1m)
Vertical
(E)
8
x
.5 Ft. (.15m)
4 (1.2m)
Total = 20
PIPE SELECTION CHART
0 1 2 3 4 5 6 7 8 9 10
Altitude x 1000 Feet
4 “ Diameter Only
3 or 4”
Diameter
30
20
10
0
Equiv
al
en
t Pipe
Le
ngth (Fe
et)
Summary of Contents for Advantage Optima 2 FS
Page 38: ...WIRING DIAGRAM PAGE 38 ...
Page 44: ...REPLACEMENT PARTS DIAGRAMS PAGE 44 5 6 8 10 13 14 9 12 7 11 ...
Page 45: ...REPLACEMENT PARTS DIAGRAMS PAGE 45 15 16 17 19 20 22 24 25 26 27 18 23 ...
Page 46: ...REPLACEMENT PARTS DIAGRAMS PAGE 46 30 37 38 40 41 29 28 33 34 39 31 32 35 ...
Page 47: ...REPLACEMENT PARTS DIAGRAMS PAGE 47 43 44 45 46 47 42 ...
Page 49: ...INSTALLATION TIPS PAGE 49 ...