INSTALLATION
♦
USA & Canada – Requires an approved noncombustible hearth or floor protector, 3/8” / (10 mm) millboard
or equivalent (k = .84, r = 1.19) to extend 6” / 150 mm to the front of the glass door.
PAGE 19
Standard Vertical Installation Configurations
Models:
Optima 2 FS and Optima 3 FS
These freestanding models may be connected to an
existing flue or by installing listed type “PL” vent pipe. If
a liner is run all the way to the top of the existing chim-
ney, the existing flue should be sealed with a steel
plate. Start a vertical run with a Tee at the back of the
stove. Other options are illustrated below.
Note: See
page 15 for Vent Termination Requirements
Exterior Vertical Vent
Vertical Vent Into A Masonry Flue
Preferred Installation
– Vertical Vent Through the
Roof
This venting configuration allows for the best stove
performance. The vertical pipe promotes natural draft
and with the chimney inside the dwelling, the flue
gases stay warm, thus rising at a consistent rate.
Interior Vertical Vent into an
Existing Class A Chimney
Wall Straps
Required Every
4 ft. Minimum
Optional Com-
plete Liner and
Listed Termina-
tion Cap
Optional Clean-Out
Access Door
Listed Rain Cap
3”
Min.
Clean-Out
Tee
Existing
Chimney
Pipe
Extend Pipe to
the Top if Exist-
ing Chimney is
Corroded or
Damaged
Pipe Increaser
3”
Min.
Flashing
Summary of Contents for Advantage Optima 2 FS
Page 38: ...WIRING DIAGRAM PAGE 38 ...
Page 44: ...REPLACEMENT PARTS DIAGRAMS PAGE 44 5 6 8 10 13 14 9 12 7 11 ...
Page 45: ...REPLACEMENT PARTS DIAGRAMS PAGE 45 15 16 17 19 20 22 24 25 26 27 18 23 ...
Page 46: ...REPLACEMENT PARTS DIAGRAMS PAGE 46 30 37 38 40 41 29 28 33 34 39 31 32 35 ...
Page 47: ...REPLACEMENT PARTS DIAGRAMS PAGE 47 43 44 45 46 47 42 ...
Page 49: ...INSTALLATION TIPS PAGE 49 ...