15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
3” (75 mm) Minimum
clearance between
wall and pipe. If you
vent to the furthest
wall, the vent pipe
must maintain a 3”
clearance parallel to
the other wall.
Top View Illustration
Wall
Top View Illustration
Wall
2" Min.
2" Min.
Wall
3” (75 mm) Minimum
clearance between wall
and pipe. If you vent to
the furthest wall, the vent
pipe must maintain a 3”
clearance parallel to the
other wall.
Top View Illustration
Wall
2" Min.
2" Min.
6” / 152 mm
Minimum
Hearth Pad / Floor Protection
12” / 305 mm From
Ground or Other Surface
45 Degree
Elbow
2” / 51 mm
Minimum
12” (305 mm)
Minimum From
Outer Wall
Figure 22 - Corner Through the Wall, Profi le 30 FS-2*
Figure 23 - Corner Through the Wall, Profi le 20 FS-2*
Figure 24 - Parallel Through the Wall, Profi le 20 FS and Profi le 30 FS
Wall
Outdoors
Standard Horizontal Installation Confi gurations
Profi le
®
20 FS-2 and Profi le 30 FS-2
* Note:
Horizontal run of pipe requires 1/4” (7 mm) rise per foot.