through. It is a good idea to extend the vertical pellet vent to the top of an oversized chimney.
MOBILE HOME INSTALLATION
For mobile home installations, the following items are recommended and may be required
(in addition to the standard installation instructions) by local, state or federal building codes:
• Stove must be permanently bolted to the floor
• Stove must have a permanent outside air source
• Stove must be permanently electrically grounded to the steel chassis of the home
CAUTION: The structural integrity of the manufactured home floor, wall and
ceiling/roof must be maintained.
Typical Installations – Freestanding Stove (cont.)
(Figure 34)
Standard Mobile Home Installation
6” Min.
Noncombustible
floor protection
Steel chassis of
mobile home
Electrical ground
to chassis
Bolt stove down
Outside air Intake and exhaust
must terminate a minimum of
12” away from each other
Floor
1” Min.
12” Min.
1” Minimum
clearance
from back
of stove to
combustible
material
6” Minimum
from front of
stove to edge of
non-com-
bustible floor
protection
Pipe must
extend a
minimum of
12 inches
from outside
wall.
31
IMPORTANT:
We recommend at least
2” to 3” min. between
the stove and wall,
to allow room for
servicing, power cord
and the hopper lid.