background image

Ill.  PARTS AND CONTROLS 

ROLL CASTORS 

DEFROST LAMP 

A yellow light turns on when 

unit  gets  into  defrosting 

mode. This  happens when 

ambient temperature is low. 

Auto Shut Off 

*

Q

.tr

'-----1---____.o 

o

� 

(9 

When the selected humidity level is reached, the dehu­

midifying function will shut off automatically 

Energy Saver 

Once the RH% is reached, the fan will still run continu­

ously to avoid high start-up amperage which makes 

the unit energy-efficient 

Auto-Restart 

In the event of a power outage, appliance restarts at 

the previously set function mode and settings when 

power is restored (not applicable to Timer Function) 

Timer Delay Switch Off 

When the appliance is ON, press the Timer button to 

activate Auto-stop function and the Timer light will 

come on. 

WATER PUMP 

POWERED OUTLET 

CURRENT TEMP/TIMER/HUMIDITY DISPLAY 

When the dehumidifier is operating, it displays the current tem­

perature on the left side and actual humidity on the right side. 

The left  LED  display  will change when timer function is acti­

vated and the user desired humidity level can be manually set 

and seen on the right LED display. 

The humidity level can be set 

within a range of 30% to 

90%RH(Relative Humidity) in 

5% increments.  This can be 

controlled by pressing the UP 

or DOWN arrows. 

°

C/

°

F SELECTOR 

Temperature conversion 

can be changed from °C 

to °F and °F to 

0

Set the desired time delay OFF hours by pressing the 

UP and DOWN and buttons. The time increments are 

1  hour up to 24 hours. When the delay time set has 

elapsed, the appliance switches off.  To cancel the 

delayed switch off function, set the time to "00" or turn 

off the appliance. 

Timer Delay Switch On 

When the appliance is OFF, press the Timer to acti­

vate Auto-start function and Timer light will come on. 

Set the desired time delay ON hours by pressing the 

UP and DOWN and buttons. The time increments are 

1  hour up to 24 hours. When the delay time set has 

elapsed, the appliance turns on. To cancel the delayed 

switch on function, set the time to "00" or turn off the 

appliance. 

Summary of Contents for RPD-561EGP

Page 1: ...idifier with Pump Gray Model RPD 561 EGP INSTRUCTION MANUAL 1 a Mii Wf iM 1 Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before...

Page 2: ...ion removal and collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference This symbol on the pro...

Page 3: ...I SAFETY PRECAUTIONS 4 II INTRODUCTION 5 Ill PARTS AND CONTROLS 6 IV OPERATION INSTRUCTIONS 7 8 V CONTINUOUS DRAINAGE 9 VI MAINTENANCE 10 VII TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 11 VIII TR...

Page 4: ...to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do...

Page 5: ...47 6 lbs 980...

Page 6: ...nd actual humidity on the right side The left LED display will change when timer function is acti vated and the user desired humidity level can be manually set and seen on the right LED display The hu...

Page 7: ...the set RH is reached or when the water bucket is full When the water bucket is full the Bucket Full indication lamp will light up and the dehumidifier will stop operating Remove the water in the buck...

Page 8: ...es of the appliance for good air circulation and 20 or more above the appliance NOTE 10 or more II II II II II 1O or more Air Intake I 10 or more 1 1 1 1 1 11 1 1 I 1O or more I I 1 1 iu t I ccccccc__...

Page 9: ...is dehumidifier also comes standard with a 3 ft drain hose To use gravity to drain your portable dehumidifier it must be installed on a level surface or at least 12 inches above the ground on a sturdy...

Page 10: ...ot clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently it is recommended to clean the air fil...

Page 11: ...ly room If your home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relati...

Page 12: ...ance must be placed in a space midifier is blocked Air grill may that does not restrict air flowing into the be dirty rear coil or out of the front grill Continuous mode is on Set the RH level and the...

Page 13: ...as an open circuit or humidity is less than 30 90 RH Humidity Sensor has short circuit or humidity is higher than 90 Lo Temperature is lower than 32 F or temperature sensor has an open circuit Hi Temp...

Page 14: ...e in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling pro...

Reviews: