background image

IV. OPERATION INSTRUCTIONS

AIR FILTERS INSTALLATION 

Your Whynter portable dehumidifier is equipped with a removable and washable filter. The filter removes 

large particles such as dust, pet hair and dander. 

WARNING: NEVER OPERATE THE DEHUMIDIFIER WITHOUT THE FILTER 

START OPERATION 

1. Ensure that the appliance is connected to the

power socket

2. Make sure the water bucket is placed in proper

position.

3. Make sure filter is installed

4. When the unit is turned on for the first time,  if

the bucket full lamp lights up, just pull out the
water bucket then push it back to the proper
position.

5. Set the relative humidity level RH% by press­

ing the up and down buttons. We recommend
setting the RH% to at least 10% lower than the
current RH%.

WHEN BUCKET FULL LAMP IS ON 

The appliance will run continuously until the set RH% is reached or when the water bucket is full. 
When the water bucket is full, the Bucket Full indication lamp will light up and the dehumidifier will 
stop operating.  Remove the water in the bucket with two hands, then place the water bucket back to 
it's proper position the machine will start operating again. This light will also illuminate when the 
bucket is removed or not properly inserted. 

DEFROST 

In  the  event frost  builds up on  the  evaporator  coils,  the  compressor  will  cycle  off  and  the  fan  will 

continue to  run until  the frost is evaporated.  This happens when the appliance is operating  in low 
temperatures (less than  53

°

F or  12

°

C),  which affects the  efficiency of the dehumidifier.  When this 

happens, the defrost lamp will turn on and the machine will go into periodic defrost mode automati­
cally.  Defrost time may vary.  If the dehumidifier freezes up, turn the appliance off for few hours and 
then restart. The appliance will not operate satisfactorily if the room temperature is below 41 

°

Summary of Contents for RPD-561EGP

Page 1: ...idifier with Pump Gray Model RPD 561 EGP INSTRUCTION MANUAL 1 a Mii Wf iM 1 Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before...

Page 2: ...ion removal and collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference This symbol on the pro...

Page 3: ...I SAFETY PRECAUTIONS 4 II INTRODUCTION 5 Ill PARTS AND CONTROLS 6 IV OPERATION INSTRUCTIONS 7 8 V CONTINUOUS DRAINAGE 9 VI MAINTENANCE 10 VII TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 11 VIII TR...

Page 4: ...to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do...

Page 5: ...47 6 lbs 980...

Page 6: ...nd actual humidity on the right side The left LED display will change when timer function is acti vated and the user desired humidity level can be manually set and seen on the right LED display The hu...

Page 7: ...the set RH is reached or when the water bucket is full When the water bucket is full the Bucket Full indication lamp will light up and the dehumidifier will stop operating Remove the water in the buck...

Page 8: ...es of the appliance for good air circulation and 20 or more above the appliance NOTE 10 or more II II II II II 1O or more Air Intake I 10 or more 1 1 1 1 1 11 1 1 I 1O or more I I 1 1 iu t I ccccccc__...

Page 9: ...is dehumidifier also comes standard with a 3 ft drain hose To use gravity to drain your portable dehumidifier it must be installed on a level surface or at least 12 inches above the ground on a sturdy...

Page 10: ...ot clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently it is recommended to clean the air fil...

Page 11: ...ly room If your home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relati...

Page 12: ...ance must be placed in a space midifier is blocked Air grill may that does not restrict air flowing into the be dirty rear coil or out of the front grill Continuous mode is on Set the RH level and the...

Page 13: ...as an open circuit or humidity is less than 30 90 RH Humidity Sensor has short circuit or humidity is higher than 90 Lo Temperature is lower than 32 F or temperature sensor has an open circuit Hi Temp...

Page 14: ...e in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling pro...

Reviews: