background image

 
 
 

LINEAR FEEDERS - MANUAL 

 

 

WIBRAMET Piotr Sokołowski

 

Ul. Gnieźnieńska 68

 

75-736 Koszalin 
NIP: 669-236-08-63 

www.wibramet.pl 
tel. 94 345 75 00 
tel. 782 972 268 
e-mail: info@wibramet.pl 

PAGE 2 

 

1. INTENDED USE 

Vibratory  linear  feeder  is  intended  for 
lengthen  feeding  line  of  orientated,  in  bowl 
feeders,  components.  Field  of  use:  automatic 
assembly,  packing,  controlling,  machining 
stations, transport of loose materials. 

The vibratory feeder is an integral part of the 
stands. 

The  device  operates  in  normal  ambient 
conditions  within  temperature  range  from  +5 
to +35

˚

C. 

2. WARNINGS 

2.1

  Do  not  connect  the  feeder  to  the  power 

supply  network  without  proper  supplying 
controller provided for this purpose. 

2.2

  Do  not  pour  any  liquid  on  the  feeder 

during its cleaning. 

2.3

  Any  maintenance  and  repair  operations 

should be done only if the power  supply plug 
is  taken  out  from  the  power  supply  network 
socket. 

2.4 

Do not operate the feeder before it is set 

on  rubber  shock  absorbers  (6)  located  in  the 
base. 

2.5

  Do  not  used  feeders  in  any  explosive 

atmosphere. 

2.6

  Do not  use feeder  without  electromagnet 

cover (3).  

2.7

  The  electromagnetic  field!  People  with 

fitted  cardiac  pacemakers  have  to  keep 
distance  of  0,5  meters  from  the  vibratory 
feeder. 

3. DESIGN DESCRIPTION 

Vibratory  linear  feeder  consist  of  following 
parts: 

 

Feeder  is  equipped  with  set  of  flat  springs 
(made 

from 

steel 

or 

plastic) 

and 

electromagnet with regulated gap. 

Electronic  controllers  with  step-less  feed 
speed control are supplied in various versions 
depending  on  individual  arrangements  made 
with the customer. 

Feeder is equipped in 4 pieces of absorber. 

Feeder  need  to  be  mount  to  device  by  holes 
into bottom of absorber. 

4. TECHNICAL DATA 

For standard feeder technical parameters see 
table no. 1. 

Feeder in standard version doesn’t have guide  

rail. 

5. MOUNTING OF  GUIDE RAIL 

To  mount  guide  rail  use  4  treaded  holes  in 
aluminium support plate (2).  

Structure of rail should be light and stiff. 

Mass of rail shouldn’t exceed the maximum –

 

see table 1. 

Recommended  dimensions  of  rail  behind  and 
in  front  of  aluminium  support  plate  (2)  are 
marked in drawing. 

It is good to lean the feeder by angle 3 to 4˚ to 

outlet.  

6. FEEDER STARTING

 

Feeder is supplied with controller. 

To  start  feeder  please  insert  controller  plug 
into electrical socket 230V/50Hz. 

Press  the  start  button  and  set  transmission 
performance by knob. 

Summary of Contents for PL1

Page 1: ...STRUCTIONS MANUAL FOR VIBRATORY LINEAR FEEDER TYPE PL 1 PL 2 PL 3 WWW WIBRAMET PL E MAIL INFO WIBRAMET PL TEL 094 345 75 00 TEL KOM 782 972 268 75 736 KOSZALIN UL GNIEŹNIEŃSKA 68 MANUFACTURING NO v 190403 ...

Page 2: ...romagnet cover 3 2 7 The electromagnetic field People with fitted cardiac pacemakers have to keep distance of 0 5 meters from the vibratory feeder 3 DESIGN DESCRIPTION Vibratory linear feeder consist of following parts Feeder is equipped with set of flat springs made from steel or plastic and electromagnet with regulated gap Electronic controllers with step less feed speed control are supplied in ...

Page 3: ... the guide rail or reduction of speed please check Size of S electromagnet operating gap for recommended gap to be applied in given feeder type see Table 1 Technical Data Flat springs 5 fixing Flat springs 5 condition replace any broken spring Guide rail fixing Electromagnet cover fixing Is feeder blocked by direct touch with any other device 9 STORAGE AND TRANSPORT Transport the feeder on board a...

Page 4: ...ail mass kg 0 2 0 7 1 0 2 0 2 0 8 0 Power supply V Hz 230 50 230 50 230 50 Absorbers 46 Sh mm Ø15 Ø15 Ø30 Flat springs mm 1 5 1 5 3 Mounting to table 4 x M4 4 x M4 4 x M8 Mounting of guide rail or hopper 4szt M5 4szt M5 4szt M8 Operating gap S mm 0 3 0 7 0 8 Bolts to regulate operating gap 2 pcs M4 2 pcs M5 2 pcs M8 Power max VA 12 25 90 Vibrating frequency 1 min 6000 6000 3000 TAB 2 IMPORTANT PAR...

Page 5: ...LINEAR FEEDERS MANUAL WIBRAMET Piotr Sokołowski Ul Gnieźnieńska 68 75 736 Koszalin NIP 669 236 08 63 www wibramet pl tel 94 345 75 00 tel 782 972 268 e mail info wibramet pl PAGE 5 ...

Page 6: ...PAGE 6 DRAWING 1 LINEAR FEEDER TYPE PL 1 ...

Page 7: ...PAGE 7 DRAWING 2 LINEAR FEEDER TYPE PL 2 ...

Page 8: ...PAGE 8 DRAWING 3 LINEAR FEEDER TYPE PL 3 ...

Reviews: