20
4
7
6
5
3
2
1
4
7
6
5
3
2
1
6.
Turn the temperature spindle until
the maximum water temperature
required is obtained.
Warmer
⇒
Turn spindle anticlockwise
Cooler
⇒
Turn spindle clockwise
7.
Refit the temperature hub with the
pip on the temperature hub aligned
with the slot on the thermostatic
cartridge. Secure the temperature
hub with the retaining screw.
8.
Refit the flow control knob in the
maximum flow position.
9.
Refit the temperature indicator trim
and temperature control knob.
Caution!
If resistance is felt when
turning the temperature knob
DO NOT
USE FORCE
to turn the knob any
further as this will
DAMAGE
internal
components.
10.
Check the temperature control can
fully turn in both directions.
11.
Check the maximum temperature
setting. If necessary repeat the
temperature adjustment until the
correct setting is achieved.
Temperature
Spindle
Align the pip on the temperature
hub with the slot in the
thermostatic cartridge.
Caution!
When resistance is felt
DO
NOT USE FORCE
to turn the spindle
any further as this is the
maximum
shower temperature
obtainable
with
the available hot water storage
temperature.
FORCE
will
DAMAGE
the internal components.
Inner
Temperature
Control
Maximum
Flow Position
Temperature
Indicator
Trim