Aquatronic 2 ultra
rEPlACiNG THE COVEr
Refit the trimplate. Turn the power selector
spindle clockwise to the position shown in
fig.
.
Turn the stabiliser valve spindle fully clockwise
until resistance is felt
(fig.)
.
On the cover turn the power selector to the OFF
position
(fig.)
and rotate the temperature
control so that it points to the ‘10’
(fig.)
.
Important:
Before finally fitting the cover,
the following steps must be taken:
a.
check the plumbing connections are
watertight.
b.
check the terminal block screws are fully
tightened.
c.
make sure the pipe and cable entering
the unit do not prevent the cover locating
correctly to the backplate.
d
.
check the power selector is set to
, the
oFF position and the temperature control
is in the ‘10’ position.
Offer the cover to the unit.
Plug the power neon located on the backplate
onto the bracket inside the cover
(fig.9)
.
Carefully locate the cover tags into the guide
pockets on the backplate and make sure the
wires are not trapped.
Guide the cover into position so that the knob
spindle locates correctly (minor adjustment may
be necessary to align the knob and spindle).
Should any difficulty arise, recheck the points
above.
While applying slight pressure to the front cover,
secure in place using the three retaining screws.
Power selector
spindle
Position flat
on top face
of spindle
!320*)
9DOYH
VSLQGOH
Fig.
Set to OFF
position
Temperature
control set to
minimum
flow position
Set to COLD
position
Fig.
Fig.
Fig.
Summary of Contents for Triton Aquatronic 2 ultra