background image

 

 

 

GB 

 

JSG12ST-S25 

Instantaneous Gas Water Heater 

 

Suitable for use in the following countries: 

 

AT, CZ, FR, GR, IE, IT, LT, 

PT, RO, SK, SI, ES, CH, GB 

INSTALLER MANUAL 

 

GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1998 (AS AMENDED) 

It is a Legal requirement  that all gas appliances must be installed by a registered 

person in accordance with the above regulations. 

Failure to install appliances correctly could lead to prosecution. It is in your own 

interest, and that of safety, to ensure that the Legal requirements are complied with. 

Read these instructions carefully before attempting to operate the appliance. Comply 

with all applicable warnings. 

Do not interfere with any sealed components, and use the appliance only in 

accordance with these instructions. 

 

RECOMMENDATIONS - 

FOR THE INSTALLER 

 

This appliance must not be installed, adjusted or adapted for use with another type of gas. 

GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1998 (as amended) 

 

It is a Legal requirement that all gas appliances must be installed by a registered person in accordance with the above 

regulations. 

Failure to install appliances correctly may lead to prosecution. 

It is in your own interest, and that of safety, to ensure that the legal requirements are complied with. 

In addition to the above regulations, this appliance must be installed in accordance with the current IEE Wiring 

regulations, Health and Safety Document No 635 'The Electricity at Work Regulations. It should also be in accordance 

with the relevant recommendations in the current editions of all relevant National Standards. Your particular attention 

is drawn to the following standards relevant to an installation in Leisure Accommodation Vehicles: 

 

BS EN 1647:2018 Leisure accommodation vehicles; Caravan holiday homes; Habitation requirements relating to 

health and safety. 

BS EN 721:2019 Leisure accommodation vehicles: Safety ventilation requirements.

 

BS EN 1949:2011+A1:2013 Specification for the installation of LPG systems for habitation purposes in leisure 

accommodation vehicles and in other vehicles. 

BS 5440-1:2008 Flueing and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd 

family gases). Specification for installation of gas appliances to chimneys and for maintenance of chimneys 

BS 6891:2015+A1:2019. Specification for the installation and maintenance of low pressure gas installation pipework of 

up to 35 mm (R1

14

) on premises.

 

 

Codes of Practice 

CoP 

 

501 

CoP 

 

502 

 

IMPORTANT: References to the above standards are for guidance only. Installers must always check to ensure that 

the references made to EN and BS standards in this document are to the latest requirements. 

The installation must be according to national and local regulations and the requirements of the CPD (construction 

products directive).     

Manufacturer’s instructions must NOT be taken in any way as over-riding statutory regulations

  

Always refer to technical information provided on the appliance data plate before installing this appliance 

Ensure that the appliance is compatible with local regulations

 

GB 

IE 

  

 

 

 

 

  

 

        

   

 

Summary of Contents for JSG12ST-S25

Page 1: ...It should also be in accordance with the relevant recommendations in the current editions of all relevant National Standards Your particular attention is drawn to the following standards relevant to a...

Page 2: ...ed so that they cannot be touched by the person using the bath or shower Your attention is drawn to the current IEE Wiring Regulations and in Scotland the electrical provisions of the Building Regulat...

Page 3: ...connection 6 GAS SUPPLY The gas pipes must be copper Do not connect plastic pipes directly to the heater It is recommended that the copper is extended to below the floor of the caravan vehicle before...

Page 4: ...side flue configuration 345 565 175 60 100 25 77 130 180 594 JSG12ST S25 rear flue configuration 345 565 205 60 100 25 107 130 180 594 J water in K gas in L water out M N O P Q WEIGHT 80 62 100 170 10...

Page 5: ...heater should be mounted on a suitable wall with sufficient structural strength to ensure adequate support 1 Mark the position of the fixing holes and the outlet aperture in the wall as indicated in d...

Page 6: ...ture for replacement part numbers NOTE The inner flue pipe of the terminal must be cut accurately and must always be 100 mm longer than the outer flue in order to ensure correct location in the termin...

Page 7: ...e diagram Eiv 8 Fit the water heater to the wall by inserting the flue pipe through the hole in the wall and securing the water heater through the fixing brackets into the pre drilled holes as detaile...

Page 8: ...go to a none illuminated condition Push the power symbol on the front panel The control panel will light up and display the temperature setting of the water supplied This temperature can be adjusted...

Page 9: ...flow rate through the water heater The flow rate of the hot water is controlled by the hot outlet tap shower The water heater can theoretically supply more than one outlet simultaneously however in pr...

Page 10: ...ce gas supply bottle 12 Flame outage Switch off mains power supply Check mains supply and fuse Restart by switching mains supply on and pressing the on off button on the control panel If problem persi...

Page 11: ...iance and consult your installer or service engineer If it is known or suspected that a fault exists on the appliance it MUST NOT be used until the fault has been rectified by a competent person 21 PR...

Page 12: ...OF THE PIPE WORK 4 OPEN THE BLEED VALVE ON THE SIDE OF THE WATER INLET FITTING A FEW TURNS TO ALLOW AIR INTO THE SYSTEM NOTE THERE IS NO DRAIN PLUG FITTED TO THE HOT WATER HEATER SIDE OF THE WATER HEA...

Page 13: ...V Control valve JSGB Burner JSGCDP Control display pcb JSGIG Ignition generator JSGFP Ignition flame sensing probe Flue System Components RSWE Elbow RSWT Terminal RSWSC01 Sealing Collar Flexible Neopr...

Page 14: ...ly electrical consumption corrected KwH 0 044 NOx emissions mg KwH 47 Indoor sound power db 61 Product Description Wall Mounted side flue room sealed fan assisted Water Heater with electronic control...

Page 15: ...ing the date of purchase model number and serial number of the product is your proof of the date of purchase or proof of purchase of the home This limited Warranty is applicable and shall be honoured...

Page 16: ...16 GB GB Widney Leisure Ltd St Mary s Road Nuneaton Warwickshire CV11 5AU Telephone 02476 377550 Fax 02476 388378 Email sales widney leisure co uk Web www widney leisure co uk W00770 Issue A...