Ku nst sto ffschweißtec hni k
Starting and operating
Chapter 5
02.08.2011
Working Instructions WIDOS 4900 CNC 3.5
Page 20 of 68
5.2. Replacing the reduction inserts
•
Unscrew the mounted reduction inserts.
•
Screw the reduction inserts with the corresponding diameter into the clamping devices.
•
If necessary (e.g. for T- pieces) the outer fixed clamping device can be dismantled by
unscrewing the three hexagon socket screws.
Dismantling of the outer fixed clamping device
5.2.1. Using small and large reduction inserts
Small reduction inserts:
•
Pipe fittings often have only a short straight surface area on which they can be clamped.
•
Fittings mostly need to be clamped in the inner clamping devices with the small reduction
inserts.
•
When fittings are to be welded (bends, T-pieces etc.), the inner small reduction insert can
also be used flush to the inside or to the outside.
R
Small reduction insert,
centered (for pipes)
Shown here:
Small reduction insert,
flush to the inside
(for bends, T-pieces)