Ku nst sto ffschweißtec hni k
Starting and operating
Chapter 5
02.08.2011
Working Instructions WIDOS 4900 CNC 3.5
Page 22 of 68
5.4. Connection with the basic machine
•
Connect the hydraulic hoses and travel measuring systems of the basic machine at the CNC
3.5 (Pos. 1 and 2).
•
Connect the heating element at the CNC 3.5 (Pos. 3) by means of the special plug and
secure it by means of the safety stirrup.
•
Connect the planer to the corresponding plug box of the CNC 3.5 (Pos. 4).
•
Connect the power line plug (No. 5) of the CNC 3.5 to the mains, and be sure to have a
correct mains voltage (230 V / 50 Hz).
5.5. Operation with emergency power supply
Do not connect any other current consumers to the emergency power supply.
Current consumers, such as drilling machines, fluorescent lamps or motors,
can generate spikes (more than 1000 V) which can
disturb the
welding
process
and might
destroy the welding aggregate
!
The emergency power supply should be maintained periodically.
For further details see the working instructions of the emergency power
supply
.
Important
: first start the emergency power supply and then the other current
consuming devices.
1
2
3
4
5